- 4 - 

ULXB Power Supply/Chargers

UL Model Reference Chart:

UL Listed
Sub-Assembly 
Board

Power Supply Series

Enclosures

AL400ULXB2

AL400ULX

Maximal11

BC300, BC400, BC800 (Maximal), Trove1 and Trove2

AL600ULXB

AL600ULX

Maximal33

BC300, BC400, BC800 (Maximal), Trove1 and Trove2

AL1012ULXB

AL1012ULX

Maximal55

BC300, BC400, BC800 (Maximal), Trove1 and Trove2

AL1024ULXB2

AL1024ULX

Maximal77

BC300, BC400, BC800 (Maximal), Trove1 and Trove2

Fig. 1 - ULXB configuration

Output Voltage Selection Dip Switch. Not applicable for AL1012ULXB and AL1024ULXB2.

**  AL1012ULXB terminals marked [– DC +]
***  AL1024ULXB2 terminals marked [– BAT +]

+  DC   

--- 

 

BAT FAIL NC    C   NO   NC   C    NO

+  BAT   -

-- 

 

AC FAIL

DC

AC

BAT

L

G

N

5A 250V

OFF   ---   24V
ON   ---   12V

1a

1b

1c***

1d**

1e*

ON

Altronix is not responsible for any typographical errors.

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.
IIULXB B04S

MEMBER

Summary of Contents for ULXB Series

Page 1: ... a power limited output is required in the end product application the DC output from the power supply must be connected to a separately Listed control unit or accessory board that provides power limited outputs The product s providing the power limited output s must be listed as appropriate for the particular end product application fire alarm burglar alarm access control and wired in accordance ...

Page 2: ...tand By 500mA Alarm 10A 4 hrs 8A Not evaluated by UL Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 NFPA 72 ANSI the Canadian Electrical Code and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Refer to Sub Assembly Installation Instructions for mounting Rev MS020119 2 Set desired DC outpu...

Page 3: ...ON OFF Loss of AC Stand by is battery supplying power OFF ON No DC output OFF OFF Loss of AC Discharged or no stand by battery No DC output Terminal Identification Terminal Legend Function Description L G N Connect 115VAC to these terminals L to hot N to neutral Fig 1a pg 4 DC AL400ULXB2 12VDC 4A or 24VDC 3A continuous output Power Limited output Fig 1d pg 4 AL600ULXB 12VDC or 24VDC 6A continuous ...

Page 4: ... Maximal77 BC300 BC400 BC800 Maximal Trove1 and Trove2 Fig 1 ULXB configuration Output Voltage Selection Dip Switch Not applicable for AL1012ULXB and AL1024ULXB2 AL1012ULXB terminals marked DC AL1024ULXB2 terminals marked BAT DC BAT FAIL NC C NO NC C NO BAT AC FAIL DC AC BAT L G N 5A 250V OFF 24V ON 12V 1a 1b 1c 1d 1e ON Altronix is not responsible for any typographical errors 140 58th Street Broo...

Reviews: