background image

 

- 2 -  

Trove3MBK3 Installation Guide

Overview:

Altronix Trove3MBK3 enclosure/backplane and brackets accommodate Altronix power supply/charger(s), sub-assemblies and Mercury controllers.

Hardware and Accessories:

•  Two (2) tamper switches (Altronix Model TS112 or equivalent).

•  Cam lock.

Mechanical:

•  16 Gauge enclosure with ample knockouts for convenient access.

•   Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. 

Product is intended for indoor use only. 

1.  Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws 

  in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.

  Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install 

  the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. 

  Install the three lower screws and make sure to tighten all screws.

2.  Mount included UL Listed tamper switches (Altronix Model TS112 or equivalent) in desired location, 

  opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from

  the right side 

(Fig. 1, pg. 2)

. Connect tamper switch wiring to the Access Control Panel input or the 

  appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.

3.  Mount Altronix power supply/charger(s), sub-assemblies and Mercury controllers to brackets (BR3M), 

  refer to drawings below.

5.  Secure BR3M brackets with boards to the backplane (TM3B) utilizing two (2) lock nuts 

(Fig. 5, pg. 3)

.

Fig. 2 - Pem location

PEM Location

Mercury Platform

Altronix

1

LP4502, LP1502, MR16IN, 

MR16OUT, MR52

ACM4(CB), ACM8(CB), ACMS8(CB), LINQ8ACM(CB), 

LINQ8PD(CB), PD8UL(CB), PDS8(CB)

2

LP4502, LP1502, MR16IN, 

MR16OUT, MR52

eFlow4NB, eFlow6NB,

eFlow102NB, eFlow104NB

3

ACM4(CB), ACM8(CB), ACMS8(CB), LINQ8ACM(CB), 

LINQ8PD(CB), PD8UL(CB), PDS8(CB)

4

LP2500, MUX8

5

ACM4(CB), LINQ8PD(CB),

PD8UL(CB), PDS8(CB)

6

LP4502, LP1502, LP2500,

MR16IN, MR16OUT, MR52, MUX8

7

eFlow4NB, eFlow6NB,

eFlow102NB, eFlow104NB

8

LP4502, LP1502, LP2500,

MR16IN, MR16OUT, MR52, MUX8

ACM4(CB), LINQ8PD(CB),

PD8UL(CB), PDS8(CB)

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

2

1

3
4

8

5

6

7

Summary of Contents for Trove3MBK3

Page 1: ...______________________________ Address __________________________________________________________ Phone __________________________ All registered trademarks are property of their respective owners More than just power Installation Guide All components of this Trove kit are UL Listed sub assemblies Please refer to the included corresponding Sub Assembly Installation Guides for further information ...

Page 2: ...er screws and make sure to tighten all screws 2 Mount included UL Listed tamper switches Altronix Model TS112 or equivalent in desired location opposite hinge Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side Fig 1 pg 2 Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device To activate alarm sign...

Page 3: ...m Mounting eFlow4NB eFlow6NB eFlow102NB eFlow104NB A ACM4 ACM4CB ACM8 ACM8CB ACMS8 ACMS8CB LINQ8ACM LINQ8ACMCB LINQ8PD LINQ8PDCB PD4UL PD4ULCB PD8UL PD8ULCB PDS8 PDS8CB B LNL 2220 LNL 4420 LNL 1320 LNL 1100 LNL 1200 LP1502 LP4502 MR52 MR16IN MR16OUT C A C C C C C C C C C C C C C C C C B B B A A C B C Fig 3 Backplane BR3M Bracket Lock Nut Fig 4 ...

Page 4: ...12 768 1mm 14 01 355 9mm 14 01 355 9mm 1 25 31 8mm 1 55 39 4mm 1 78 45 2mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36 12 917 5mm 33 63 854 2mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altron...