T2AGK3F8

8 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove2 enclosure with TAG2 Altronix/AMAG backplane

  -  One (1) eFlow6NB - Power Supply/Charger

  -  One (1) ACM8 - Fused Access Power Controller

  -  One (1) VR6 - Voltage Regulator

  -  One (1) PDS8 - Dual Input Fused Power Distribution Module

T2AGK7F12

12 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove2 enclosure with TAG2 Altronix/AMAG backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) ACM8 - Fused Access Power Controller

  -  One (1) ACM4 - Fused Access Power Controller

  -  One (1) VR6 - Voltage Regulator

  -  One (1) PDS8 - Dual Input Fused Power Distribution Module

T2AGK75F12

12 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove2 enclosure with TAG2 Altronix/AMAG backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

  -  One (1) ACM8 - Fused Access Power Controller

  -  One (1) ACM4 - Fused Access Power Controller

  -  One (1) PD4UL - Fused Power Distribution Module

Access & Power Integration

Rev. TAGK_042319

Installing Company:  _____________________ Service Rep. Name:  __________________________________________ 

Address:  ________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners. 

More than just power.™

Installation Guide

All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Summary of Contents for TROVE T2AGK3F8

Page 1: ...Kit with Fused Outputs Fully assembled kit includes Trove2 enclosure with TAG2 Altronix AMAG backplane One 1 eFlow104NB Power Supply Charger One 1 eFlow102NB Power Supply Charger One 1 ACM8 Fused Acc...

Page 2: ...the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware...

Page 3: ...T8 1 2 3 4 5 6 7 8 10 10 3 3 3 3 3 3 3 3 Out2 1 off 2 Out3 1 off 2 Out4 1 off 2 Out5 1 off 2 Out6 1 off 2 Out7 1 off 2 Out8 1 off 2 Altronix PDS8 VR6 mounted under PDS8 AMAG M4000 AMAG M4000 NC C NO N...

Page 4: ...x ACM4 INP1 DM1 OFF IN1 IN2 Out1 1 off 2 DM1 DM2 DM2 Common Common INP2 IN2 Fuse IN1 Fuse Common Power Outputs NEG N P OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 1 2 3 4 5 6 7 8 10 10 3 3 3 3 3 3 3 3 Out...

Page 5: ...PUT 4 CONTROL POWER INP T RET INTERFACE NO C NC FACP Altronix ACM4 Altronix eFlow104NB DC BAT L G N Altronix PD4UL F1 F2 F3 F4 1P 1N 2P 2N 3P 3N 4P 4N P N NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL...

Page 6: ...6 Trove AMAG M4000 Kits Notes...

Page 7: ...Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC batt...

Page 8: ...imate 27 25 x 21 5 x 6 5 692 15mm x 546 1mm x 165 1mm G 1 25 31 75mm 1 25 31 75mm 6 25 158 75mm 6 25 158 75mm 6 75 171 45mm 8 25 209 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59mm...

Reviews: