T1RAL13F8P8

Installation Instructions for T1RAL13F8P8:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having 
jurisdiction. Product is intended for indoor use only. 
1.  Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2.  In order to mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) turn the enclosure upside down. 
 

Punch out the knockout in designated location, on the back of the unit, from outside of the drawer (Fig. 3, pg. 3)

 

Insert the tamper switch into the knockout from outside of the drawer with the button facing outwards and spaded connectors inside 

 

the drawer. Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. 

 

To activate alarm signal open the rack drawer.

3.  Slide the Trove rack enclosure into an open 2U location in the rack cabinet.
4.  Utilizing proper fasteners attach front ears to the rack rails.
5.  Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6.  Make sure that all internal cofigurations (wiring, voltage selection, switch settings, etc.) are complete before mounting backplane back 
 

into enclosure.

7.  Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB and eFlow6NB, and corresponding sub-assembly 
 

Installation Guides for ACM8(CB) and PD8UL for further instructions.

Fig. 3

Tamper Switch mounting location

Back of the drawer, 

viewed from outside.