Altronix TROVE Mercury Series T3MK75F16 Installation Manual Download Page 6

 

- 6 -  

T3MK Kits

eFlow Power Supply/Chargers can be Controlled and Monitored while 

Reporting Power/Diagnostics from Anywhere over the Network...

LINQ2 Mounts Inside any Trove Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep 
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini-
mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost 
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR). 

LINQ2 

Features:

-  UL Listed in the U.S. and Canada.
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, 
  output state change and unit temperature.
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays.
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
-  Email and Windows Dashboard notifications
-  Event log tracks history.
-  Secure Socket Layer (SSL).
-  Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Altronix eFlow

Power Supply

Network Connection:

Installation, Programming

and Monitoring

Summary of Contents for TROVE Mercury Series T3MK75F16

Page 1: ...enclosure with TM3 Altronix Mercury backplane One 1 eFlow104NB Power Supply Charger One 1 eFlow102NB Power Supply Charger Two 2 ACM8CB PTC Protected Access Power Controllers One 1 PD8ULCB PTC Protect...

Page 2: ...e Dimensions H x W x D 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all loc...

Page 3: ...tandoffs and depress onto snap on standoffs Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP...

Page 4: ...ffs and depress onto snap on standoffs Fig 3a pg 4 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502...

Page 5: ...T3MK Kits 5 Notes...

Page 6: ...ures UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery s...

Page 7: ...T3MK Kits 7 TM3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 11 5 292 1mm 1 0 25 4mm 28 0 711 2mm 23 0 584 2mm 11 5 292 1mm 2 0 50 8mm 34 0 863 6mm 1 0 25 4mm 27 0 685 8mm 6 5 165 1mm...

Page 8: ...mm 9 5 241 3mm 1 25 31 75mm 1 55 39 37mm 1 78 45 21mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36...