Altronix TROVE Mercury Series T3MK75F16 Installation Manual Download Page 1

T3MK75F16

16 Door Kit with Fused Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

  -  Two (2) ACM8 - Fuse Protected Access Power Controllers

  -  One (1) PD8UL - Fuse Protected Power Distribution Module

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

T3MK77F16

16 Door Kit with Fused Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  Two (2) eFlow104NB - Power Supply/Chargers

  -  Two (2) ACM8 - Fuse Protected Access Power Controllers

  -  Two (2) PD8UL - Fuse Protected Power Distribution Modules

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

T3MK75F16D

16 Door Kit with PTC Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

  -  Two (2) ACM8CB - PTC Protected Access Power Controllers

  -  One (1) PD8ULCB - PTC Protected Power Distribution Module

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

T3MK77F16D

16 Door Kit with PTC Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  Two (2) eFlow104NB - Power Supply/Chargers

  -  Two (2) ACM8CB - PTC Protected Access Power Controllers

  -  Two (2) PD8ULCB - PTC Protected Power Distribution Modules

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

Access & Power Integration

Rev. T3MK071818

Installing Company:  _____________________ Service Rep. Name:  __________________________________________ 

Address:  ________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners. 

More than just power.™

Installation Guide

Summary of Contents for TROVE Mercury Series T3MK75F16

Page 1: ...enclosure with TM3 Altronix Mercury backplane One 1 eFlow104NB Power Supply Charger One 1 eFlow102NB Power Supply Charger Two 2 ACM8CB PTC Protected Access Power Controllers One 1 PD8ULCB PTC Protect...

Page 2: ...e Dimensions H x W x D 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all loc...

Page 3: ...tandoffs and depress onto snap on standoffs Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP...

Page 4: ...ffs and depress onto snap on standoffs Fig 3a pg 4 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502...

Page 5: ...T3MK Kits 5 Notes...

Page 6: ...ures UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery s...

Page 7: ...T3MK Kits 7 TM3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 11 5 292 1mm 1 0 25 4mm 28 0 711 2mm 23 0 584 2mm 11 5 292 1mm 2 0 50 8mm 34 0 863 6mm 1 0 25 4mm 27 0 685 8mm 6 5 165 1mm...

Page 8: ...mm 9 5 241 3mm 1 25 31 75mm 1 55 39 37mm 1 78 45 21mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36...

Reviews: