Overview:

Altronix Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure with factory installed Altronix power supply/
charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in 
a single enclosure.

Configuration Chart:

Altronix

Model Number

Nominal DC Output 

Voltage

Maximum 

Supply

Current for 

Main and Aux. 

Outputs on Power 

Supply board 

and ACM4CB/

ACM8CB 

Access Power 

Controller’s 

outputs

Fail-Safe/Fail-Secure Auto- Resettable Outputs

120VAC 60Hz Input Current (A)

Current Per ACM4CB/ACM8CB Output 

(A)

Power Supply Board Input Fuse Rating

Power Supply Board Battery Fuse Rating

ACM4CB/ACM8CB Board Input Fuse Rating

ACM4CB/ACM8CB Board  Output PTC Rating

PDS8CB Board Input Fuse Rating

PDS8CB Board Output PTC Rating

PD8ULCB Board Output PTC Rating

Power 

Supply 1

Power 

Supply 2

[DC] [Aux] [DC] [Aux]

Output Range  (VDC)

Output Range  (VDC)

Output Range  (VDC)

Output Range  (VDC)

T2MK3F4D

20.19-

26.4

20.19-

26.4

----

----

24VDC @ 5.8A

4

3.5

2.0

5A/

250V

10A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK3F4DQ

20.19-

26.4

20.19-

26.4

----

----

24VDC @ 5.8A

4

3.5

2.0

5A/

250V

10A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK3F8D

20.19-

26.4

20.19-

26.4

----

----

24VDC @ 5.8A

8

3.5

2.0

5A/

250V

10A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK3F8DQ

20.19-

26.4

20.19-

26.4

----

----

24VDC @ 5.8A

8

3.5

2.0

5A/

250V

10A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK7F8D

20.17-

26.4

20.28-

26.4

----

----

24VDC @ 9.2A

8

4.5

2.0

6.3A/
250V

15A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK7F8DQ

20.17-

26.4

20.28-

26.4

----

----

24VDC @ 9.2A

8

4.5

2.0

6.3A/
250V

15A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK75F16D

20.17-

26.4

20.28-

26.4

9.7-

13.2

10.03-

13.2

12VDC @ 9.3A
24VDC @ 9.2A

16

8

2.0

6.3A/250V

5A/250V

15A/

32V

10A/

250V

2A

----

----

2A

T2MK75F16DQ

20.17-

26.4

20.28-

26.4

9.7-

13.2

10.03-

13.2

12VDC @ 9.3A
24VDC @ 9.2A

16

8

2.0

6.3A/250V

5A/250V

15A/

32V

10A/

250V

2A

----

----

2A

T2MK77F16D

20.17-

26.4

20.28-

26.4

20.17-

26.4

20.28-

26.4

24VDC @ 9.2A

16

9

2.0

6.3A/
250V

15A/

32V

10A/

250V

2A

10A/

250V

2A

----

T2MK77F16DQ

20.17-

26.4

20.28-

26.4

20.17-

26.4

20.28-

26.4

24VDC @ 9.2A

16

9

2.0

6.3A/
250V

15A/

32V

10A/

250V

2A

10A/

250V

2A

----

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities 
having jurisdiction. Product is intended for indoor use only. 
1.  Remove backplane(s) from enclosure. Do not discard hardware.
2.  Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws 
 

in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.

 

Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the

 

enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.

3.  Mount included UL Listed tamper switch (Honeywell Model 112 or equivalent) in desired location, opposite hinge. Slide the
 

tamper switch bracket onto the edge of the enclosure approximately 2” from the right side

 

(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the

 

appropriate UL Listed reporting device. To activate alarm signal open the

 

door of the enclosure.

4.  Refer to the eFlow Power Supply/Charger Installation Guide (eFlow6NB, eFlow102NB, 
 

eFlow104NB) and Sub-Assembly Installation Guide for the following models:

 

ACM4CB, ACM8CB, LINQ2, PDS8CB, VR6 for further installation instructions.

5.  Fasten snap on standoffs onto metal pems configuration of backplane depending on the 
 

Mercury access controller (Fig. 2-5, pg. 3-6).

6.  Position Mercury access controller module over corresponding standoffs and depress onto 
 

snap on standoffs (Fig. 2-5, pg. 3-6).

7.  Mount backplane to enclosure with hardware.

Edge of 

Enclosure 

to Access Control Panel 

or U.L. Listed 

Reporting Device 

Enclosure 

Honeywell

model # 112

Tamper Switch

or equivalent

(provided)

Fig. 1

Summary of Contents for T2MK3F4D

Page 1: ... Trove2 enclosure with TM2 backplane 1 eFlow104NB Power Supply Charger 1 ACM8CB PTC Access Power Controller 1 VR6 Voltage Regulator 1 PDS8CB Dual Input Power Distribution Module T2MK7F8DQ Fully assembled kit includes Trove2 enclosure with TM2 backplane 1 eFlow104NB Power Supply Charger 1 LINQ2 Network Communications Module 1 ACM8CB PTC Access Power Controller 1 VR6 Voltage Regulator 1 PDS8CB Dual ...

Page 2: ... 4 24VDC 9 2A 16 9 2 0 6 3A 250V 15A 32V 10A 250V 2A 10A 250V 2A T2MK77F16DQ 20 17 26 4 20 28 26 4 20 17 26 4 20 28 26 4 24VDC 9 2A 16 9 2 0 6 3A 250V 15A 32V 10A 250V 2A 10A 250V 2A Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Rem...

Page 3: ...B 8 PTC output Dual Input Power Distribution Module T2MK3F8D One 1 eFlow6NB 24VDC 6A Power Supply Charger one 1 ACM8CB 8 PTC output Access Power Controller one 1 VR6 24VDC input to 12VDC output Voltage Regulator and one 1 PDS8CB 8 PTC output Dual Input Power Distribution Module T2MK3F8DQ One 1 eFlow6NB 24VDC 6A Power Supply Charger one 1 LINQ2 Network Communication Module one 1 ACM8CB 8 PTC output...

Page 4: ...PTC output Dual Input Power Distribution Module T2MK7F8DQ One 1 eFlow104NB 24VDC 10A Power Supply Charger one 1 LINQ2 Network Communication Module one 1 ACM8CB 8 PTC output Access Power Controller one 1 VR6 24VDC input to 12VDC output Voltage Regulator and one 1 PDS8CB 8 PTC output Dual Input Power Distribution Module Fig 3 LINQ2 T2MK7F8DQ Altronix eFlow104NB Altronix ACM8CB Altronix PDS8CB VR6 ...

Page 5: ...put Power Distribution Module T2MK75F16DQ One 1 eFlow104NB 24VDC 10A Power Supply Charger and one 1 eFlow102NB 12VDC 10A Power Supply Charger one 1 LINQ2 Network Communication Module two 2 ACM8CB 8 PTC output Access Power Controller and one 1 PD8ULCB 8 PTC output Power Distribution Module Fig 4 LINQ2 T2MK75F16DQ Altronix eFlow102NB Altronix ACM8CB Altronix eFlow104NB Altronix ACM8CB Altronix PD8UL...

Page 6: ...ut Power Distribution Module T2MK77F16DQ Two 2 eFlow104NB 24VDC 6A Power Supply Charger one 1 LINQ2 Network Communication Module two 2 ACM8CB 8 PTC output Access Power Controller one 1 VR6 24VDC input to 12VDC output Voltage Regulator and one 1 PDS8CB 8 PTC output Dual Input Power Distribution Module Fig 5 LINQ2 T2MK77F16DQ Altronix eFlow104NB Altronix ACM8CB Altronix eFlow104NB Altronix ACM8CB Al...

Page 7: ...ne to enclosure with hardware Altronix Sub Assemblies and or Adapters 1 Fasten nylon snap on standoffs to pems which match the hole pattern for Altronix Sub Assemblies Fig 6 6a pg 7 2 Mount boards to standoffs utilizing pan head screws provided with the product or by depressing board onto snap on standoff Fig 6 pg 7 Note For GB1 please use standoffs supplied with the adapter Access Controller Posi...

Page 8: ...27 25 x 21 5 x 6 5 692 15mm x 552 5mm x 165 1mm G 1 25 31 75mm 1 25 31 75mm 6 25 158 75mm 6 25 158 75mm 6 75 171 45mm 8 25 209 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59mm 1 00 25 4mm 2 00 50 8mm 1 25 31 75mm 2 00 50 8mm 2 00 50 8mm 5 25 133 35mm 5 25 133 35mm 7 00 177 79mm 2 00 50 8mm 2 00 50 8mm 27 00 685 8mm 3 50 88 9mm 0 5625 14 29mm 2 415 61 34mm 0 685 17 399mm 1 77 44 ...

Reviews: