A

B

C

D

D

C

B

A

Altronix

AL400ULXB2

Flying

Leads

+   IN  -         +OUT-

ON-5V
OFF-12V

Altronix - VR6

TRG

TRIGGER

INPUT

ACM4

ACCESS POWER

CONTROLLER

LED1 

LED2 

LED3 

LED4

MAIN

OUTPUT 1

NC   C   NO  COM NC   C   NO  COM

NC   C   NO  COM NC   C   NO  COM

OUTPUT 2

OUTPUT 3

IN  GND

1

IN  GND

2

IN  GND

3

IN  GND

4

OUTPUT 4

-- 

       

+

CONTROL

-- 

       

+

POWER

+INP-      

T      +RET

-

INTERF

ACE

NO     C      NC

FACP

Altronix - ACM4(CB)

L       G        

N

BAT FAIL  NC  C  NO  NC  C  NO 

 

AC  FAIL

AC

+ BAT -

+ DC -

DC

BAT

F1

Off - 24V

On - 12V

SW1

ON

T1MK14 and T1MK14D: Configuration of Mercury Boards:

1.  Fasten snap on spacers onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller 

(Fig. 2, pg. 3)

.

2.  Position access controller module over corresponding spacers and depress onto snap on spacers 

(Fig. 2a, pg. 3)

.

3.  Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models:

Mercury Access Controller

Pem Mounting

EP1502, LP1502, MR52, MR16IN, MR16OUT

A

EP1501, LP1501, MR51e, MR62e

B

MR50

C

EP2500, LP2500, MUX8

D

Fig. 2

Snap On

Spacer

Mercury Board

Backplane

Pem

Fig. 2a

Summary of Contents for T1MK14

Page 1: ...M4CB PTC Access Power Controller T1MK14SD 4 Door Kit with PTC Outputs Fully assembled kit includes Trove1 enclosure with TM1 Altronix Mercury backplane 1 AL400ULXB2 Power Supply Charger 1 VR6 Voltage Regulator 1 ACM4CB PTC Access Power Controller 1 PDS8CB Dual Input Power Distribution Module Rev T1MKL113021 Installing Company __________________________ Service Rep Name ____________________________...

Page 2: ... NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two 2 keyholes in the enclosure Install two upper fasteners and screws in the wall with the screw heads protruding Place the enclosure s upper keyholes over the two ...

Page 3: ...FAIL AC BAT DC DC BAT F1 Off 24V On 12V SW1 ON T1MK14 and T1MK14D Configuration of Mercury Boards 1 Fasten snap on spacers onto metal pems configuration A B C or D of backplane depending on the access controller Fig 2 pg 3 2 Position access controller module over corresponding spacers and depress onto snap on spacers Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Positi...

Page 4: ... off 2 Out5 1 off 2 Out6 1 off 2 Out7 1 off 2 Out8 1 off 2 Altronix AL400ULXB2 L G N BAT FAIL NC C NO NC C NO AC FAIL AC BAT DC DC BAT F1 Off 24V On 12V SW1 ON T1MK14S and T1MK14SD Configuration of Mercury Boards 1 Fasten snap on spacers onto metal pems configuration A B C or D of backplane depending on the access controller Fig 3 pg 4 2 Position access controller module over corresponding spacers...

Page 5: ... 5 Trove1 Mercury ULXB Kits Installation Guide Notes ...

Page 6: ... 6 Trove1 Mercury ULXB Kits Installation Guide Notes ...

Page 7: ... 7 Trove1 Mercury ULXB Kits Installation Guide Notes ...

Page 8: ... 9mm 6 5 165 1mm 1 5 38 1mm 8 5 215 9mm 6 5 165 1mm 4 5 114 3mm 13 0 330 2mm 0 6 15 2mm 14 5 321 3mm 1 45 36 8mm 7 25 184 2mm 1 95 49 5mm 1 1 27 9mm 0 6 15 2mm 0 57 14 5mm 18 0 457 2mm 1 25 31 8mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warran...