background image

- 2 - 

ReServ

Overview:

ReServ Video Surveillance UPS units are designed to provide power for 24VAC and/or 12VDC cameras during normal or 

power outage conditions. True sine wave regulated AC outputs and/or regulated DC outputs.

ReServ Series Video Surveillance UPS Configuration Reference Chart:

Altronix

Model 

Number

Output/Supply

Current (A)

Ambient

Temperature

Input

Rating

PTC 

Protected 

Power-

Limited 

Outputs

24VAC Outputs

12VDC Outputs

Agency 

Listings

UL Listings and

File Numbers

ReServ1

24VAC @ 4A (100VA)

& 12VDC @ 2A

-33º to 30º C

115VAC

60Hz, 3.5A

16

12

4

UL File # 

E329542

UL 60950-1

UL/CUL Listed

for

Information

Technology

Equipment.

24VAC @ 3.5A (85VA)

& 12VDC @ 2A

-33º to 42º C

ReServ2

24VAC @ 4A (100VA)

-33º to 30º C

115VAC

60Hz, 3.5A

16

16

----

24VAC @ 3.5A (85VA) -33º to 42º C

ReServ3

12VDC @ 8A

-33º to 42º C

115VAC

60Hz, 3.5A

16

----

16

Specifications:

Stand-by Specifications:

ReServ1

Stand-by Batteries

4A (100VA) load at 24VAC and 2A load at 12VDC max.

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH*

90 minutes

ReServ2

Stand-by Batteries

4A (100VA) max. load at 24VAC

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH*

90 minutes

ReServ3

Stand-by Batteries

8A (100VA) max. load at 12VDC

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH*

90 minutes

*When using 12AH batteries or larger a separate UL Listed battery enclosure must be installed. Optional UL Listed 

battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods.

Output:

•  PTC protected power-limited outputs are rated @ 1A.

Battery Backup:

•  Built-in charger for sealed lead acid or gel type batteries. 

•  Automatic switchover to stand-by battery when AC fails.

Supervision:

•  AC fail supervision (form “C” contacts). 

•  Low battery supervision (form “C” contacts). 

Visual & Audio Indicators:

•  AC/DC power LED indicators.

•  Individual power output LED indicators.

•  Low voltage input and Shutdown LED indicators.

•  Audio AC Fail and Battery Fail indicator.

Additional Features:

•  True sine wave regulated AC outputs (ReServ1 &

  ReServ2). Regulated DC outputs (ReServ1 & ReServ3).

•  Unit maintains camera synchronization. 

•  Ease of installation saves time and eliminates costly labor.

Enclosure Dimensions 

(H x W x D approximate)

:

  13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)

•  Enclosure accommodates up to

  two (2) 12VDC/7AH batteries.

Summary of Contents for ReServ1

Page 1: ...A total supply current 24VAC and 2A total supply current 12VDC PTC protected power limited outputs ReServ2 Sixteen 16 true sine wave regulated 24VAC outputs 4A total supply current PTC protected power limited outputs ReServ3 Sixteen 16 regulated 12VDC outputs 8A total supply current PTC protected power limited outputs Rev 082510 More than just power ...

Page 2: ...ies 4A 100VA max load at 24VAC Two 2 12VDC 7AH 45 minutes Two 2 12VDC 12AH 90 minutes ReServ3 Stand by Batteries 8A 100VA max load at 12VDC Two 2 12VDC 7AH 45 minutes Two 2 12VDC 12AH 90 minutes When using 12AH batteries or larger a separate UL Listed battery enclosure must be installed Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods Out...

Page 3: ...s devices to the terminals marked P 1 4 N 1 4 Fig 1 pg 5 Connect 24VAC cameras devices to the terminals marked 5 16 Fig 1 pg 5 ReServ2 Connect 24VAC cameras devices to the terminals marked 1 16 Fig 2 pg 6 ReServ3 Connect 12VDC cameras devices to the terminals marked P 1 16 N 1 16 Fig 3 pg 7 7 Connect batteries to the terminals marked BAT Figs 1 3 pg 5 7 Use two 2 12VDC batteries connected in serie...

Page 4: ...osed NC and C are open BAT FAIL NO C NC Form C dry contacts used to signal low battery voltage or loss of battery voltage Under normal con ditions terminals marked NO and C are open NC and C are closed During a trouble condition termi nals marked NO and C are closed and NC and C are open BAT Stand by battery connections Maximum charge current 0 7A ReServ Board Terminal Legend Function Description ...

Page 5: ...arately Supervised Non power limited CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions Non power limited 5A 250V Unswitched 115VAC 60Hz 3 5A power mains non power limited 24VAC Power Limited Outputs 12VDC Power Limited Outputs Note Two 2 12VDC rechargeable batteries connected in series required power limited AC DC ...

Page 6: ...able Battery order separately Supervised Non power limited CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteires according to the instructions Non power limited 5A 250V Unswitched 115VAC 60Hz 3 5A power mains non power limited Note Two 2 12VDC rechargeable batteries connected in series required power limited 24VAC Outputs AC DC ...

Page 7: ...rect type Dispose of used batteires according to the instructions Non power limited 5A 250V Unswitched 115VAC 60Hz 3 5A power mains non power limited Note Two 2 12VDC rechargeable batteries connected in series required 12VDC Power limited Outputs P N 3 OUT 4 3 4V adjust P N 5 OUT 6 5 6V adjust P N 7 OUT 8 7 8V adjust P N 9 OUT 10 9 10V adjust P N 11 OUT 12 11 12V adjust P N 13 OUT 14 13 14V adjust...

Page 8: ...onix com Lifetime Warranty Made in U S A IIReServ F15P 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm 5 10 130mm 5 10 130mm 13 0 330mm 5 10 130mm 6 5625 167mm 1 20 31mm 1 20 31mm 1 20 31mm 3 25 83mm 3 25 83mm 3 25 83mm 3 25 83mm 1 0 25mm 1 0 25mm 10 5 267mm 1 0 25mm 1 0 25mm 0 75 19mm 0 75 19mm 0 9375 24mm 0 9375 24mm 11 0 279mm 12 5 318mm Enclosure Dimensions H x W x D approximate ...

Reviews: