R615DC8220 Series
- 3 -
P
N
Power
LEDs
Power
LEDs
+
DC OUTPUT
-
- BA
T
+
AC
AC
DC
AC
Voltage
Adjustment
PTC1
PTC1 PTC1 PTC1
PTC1
PTC1 PTC1 PTC1
Used on R615DC8CB220
Removable Terminal
Block
Strain Relief
Line Cord
Power Switch
Trimpot
Fig. 1
Fig. 1a
Fig. 1b
Fig. 1c
Fig. 1d
Terminal Identification:
AL400ULB - Power Supply Board
Terminal Legend
Function/Description
AC/AC
Low voltage AC input (24VAC 100VA) Altronix part #T24130/220
+ DC –
6VDC-15VDC @ 4A total continuous output.
PD8/PD8CB - Distribution Module
Terminal Legend
Function/Description
1P - 8P
Positive DC output
1N - 8N
Negative DC output
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may
be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
CAUTION: To reduce the risk of electric shock do not open
enclosure. There are no user serviceable parts inside. Refer servicing
to qualified service personnel.