background image

R615DC8220 Series 

- 3 - 

P

N

Power

LEDs

Power

LEDs

DC OUTPUT 

-

-  BA

 +

AC

AC

DC

AC

Voltage

Adjustment

 PTC1

 PTC1  PTC1  PTC1

 PTC1

 PTC1  PTC1  PTC1

Used on R615DC8CB220

Removable Terminal

Block

Strain Relief

Line Cord

Power Switch

Trimpot

Fig. 1

Fig. 1a

Fig. 1b

Fig. 1c

Fig. 1d

Terminal Identification:

AL400ULB - Power Supply Board

Terminal Legend

Function/Description

AC/AC

Low voltage AC input (24VAC 100VA) Altronix part #T24130/220

+ DC –

6VDC-15VDC @ 4A total continuous output.

PD8/PD8CB - Distribution Module

Terminal Legend

Function/Description

1P - 8P

Positive DC output

1N - 8N

Negative DC output

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may 
be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying 
the appliance.

CAUTION: To reduce the risk of electric shock do not open 
enclosure. There are no user serviceable parts inside. Refer servicing 
to qualified service personnel.