- 2 -
Pace1PRMTHT Installation Guide
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes
and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
Pace1PTM and Pace1PRMHT are not intended to be connected to outside plant leads and should be installed
indoors within the protected premises. Pace1PRMHT and Pace1PTM are intended for indoor use only.
1.
Pace1PRMHT installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole
(Fig. 2a, pg. 3)
. Unit should be mounted in proximity to ethernet switch/network, NVR or video server.
b.
Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [PoE Input]
(Fig. 2, pg. 3)
.
c.
CAT5e or higher:
Connect CAT5e or higher to connector marked [RJ45 Link]
(Fig. 2, pg. 3)
.
2.
Pace1PTM installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole
(Fig. 2a, pg. 3)
. Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out]
(Fig. 2, pg. 3)
.
c.
CAT5e or higher:
Connect CAT5e or higher to connector marked [RJ45 Link]
(Fig. 2, pg. 3)
.
Technical Specifications:
Parameter
Description
Connections
RJ45 for ethernet link.
Input power
requirements
Midspan or endspan port connected.
PoE compliant to IEEE 802.3af (15W) and PoE+ compliant to IEEE 802.3at (30W)
Indicators
Yellow (RJ45 connector):
On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector):
On - 100Base-TX.
Green:
PoE Active.
Environmental
Conditions
Operating Ambient Temperature (UL60950-1):
Pace1PRMHT:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 25W: – 40ºC to 49ºC (– 40ºF to 120ºF).
Pace1PTM:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 25W: – 40ºC to 70ºC (– 40ºF to 158ºF).
For 30W – 40ºC to 60ºC (– 40ºF to 140ºF).
Relative Humidity:
20 to 85%, non-condensing.
Storage Temperature:
– 40ºC to 75ºC (– 40ºF to 167ºF).
Operating Altitude:
– 304.8 to 2,000m.
Regulatory
Compliance
CE European Conformity.
Weights (approx.)
Product: 0.25 lb. (0.11 kg) | Shipping: 0.42 lb. (0.19 kg).
Fig. 1
Pace1PRMHT Pace1PTM
Structured Cable
to Midspan/Endspan
Green LED
indicates PoE
Present from
Midspan/Endspan
Green LED
indicates PoE
being transmitted
to Pace1PTM
CAT5 or higher
from Pace1PTM
N/A
Structured Cable from
Camera/Device
Green LED
indicates PoE
transmitted to
Camera/Device
Green LED
indicates PoE
received
from Pace1PRMHT
CAT5 or higher
from Pace1PRMHT
N/A