Altronix NetWaySP4 Installation Manual Download Page 6

 

- 6 - 

NetWaySP4 Series Installation Guide

Configuring Units for Network Connection

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Please be sure to visit altronix.com for latest

firmware and installation instructions

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Factory Default Settings

•  IP Address:  

192.168.168.168

•  User Name:  

admin

•  Password:  

admin

1.  Set the static IP address for the laptop to be used for programming to the same network IP address as the 

  NetwaySP4. The default address of the NetwaySP4 is 192.168.168.168, E.I. 192.168.168.200.

2.  Connect one end of the network cable to the network jack on the NetwaySP4 and the other to the network 

  connection of the laptop.

3.  Open a browser on the computer and enter “192.168.168.168” into the address bar. 

  A dialog box Authentication Required will appear requesting both user name and password. 

  Enter the default values here. Click on the button labeled 

Log In

4.  The status page of the NetWaySP4 will appear. Click on the tab labeled 

Network Settings

  This will open the Network Setting screen. In this screen the MAC Address of the NetWaySP4 module will 

  be found along with the Network Settings and Email Settings.

Network Settings:

In the IP Address Method field select the method that the IP Address for the NetWaySP4 will be obtained 

(STATIC or DHCP), then follow the appropriate steps.

Static: 

  A.  IP Address: Enter the IP address assigned to the NetWaySP4 by the network administrator.

  B.  Subnet Mask: Enter the Subnet of the network.

  C.  Gateway: Enter the TCP/IP gateway of the network access point (router) being used. 

    Gateway configuration is required to properly receive emails from the device.

  D.  HTTP Port: Enter the HTTP port number assigned to the NetWaySP4 module by the network 

    administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not 

    encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily 

    for use with LAN connections.

  E.  HTTPS Port: Enter the HTTPS port number assigned to the NetWaySP4 module by the network 

    administrator to allow remote access and monitoring. The default inbound port setting is 443. 

    Being encrypted and more secure, HTTPS is highly recommended for remote access.

  F.  Click the button labeled 

Submit Network Settings

    A dialog box will display “New network settings will take effect after the server is rebooted”. Click 

OK

.

DHCP:

  A.  After selecting DHCP in the IP Address Method field click the button labeled 

Submit Network Settings

    A dialog box will display “New network settings will take effect after the server is rebooted”. Click 

OK

    Next, click on the button labeled 

Reboot Server

. After rebooting the NetWaySP4 will be set in the DHCP 

    mode. The IP address will be assigned by the router when the NetWaySP4 is connected to the network. 

    It is recommended to have the assigned IP Address reserved to ensure continued access 

    (see the network administrator). 

  B.  Subnet Mask: When operating in DHCP, the router will assign the subnet mask values.

  C.  Gateway: Enter the TCP/IP gateway of the network access point (router) being used.

  D.  HTTP Port: Enter the HTTP port number assigned to the NetWaySP4 module by the network administrator 

    to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and 

    unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with 

    LAN connections. 

Summary of Contents for NetWaySP4

Page 1: ...FP 1G Link and 4 port PoE switch uses external power supply NEMA4 4X IP66 rated Outdoor enclosure NetWaySP4PL Dual Fiber Optic SFP 1G Link 4 port PoE switch and power supply Backplane version NetWaySP4B Dual Optic SFP 1G Link and 4 port PoE switch Board only DOC NetWaySP4 Rev 032917 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Add...

Page 2: ...l Specifications pg 5 Configuring Units for Network Connection pg 6 Factory Default Settings pg 6 Network Settings pg 6 Static pg 6 DHCP pg 6 Secure Network Setup pg 7 Factory Reset Option pg 7 VLans pg 8 VLan Setup Drawing pg 9 Typical Applications Drawings pg 10 11 Wall Mount Installation pg 12 Pole Mounting Using Optional Pole Mount Kit pg 12 Mechanical Drawings and Dimensions pg 13 16 ...

Page 3: ...e LEDs for each port ALOS LED indicates fiber connection for SFP port Heartbeat LED indicates proper operation of the unit LINQ Technology Remote network management allows for camera device reset and monitoring PoE port management via Dashboard IP management program Provides local and or remote access to critical information via LAN WAN Email and Windows Dashboard Alert notifications report real t...

Page 4: ... screw heads protruding Place the enclosure s upper keyholes over the two 2 upper screws level and secure Mark the position of the lower two 2 holes Remove the enclosure Drill the lower holes and install two fasteners Place the enclosure s upper keyholes over the two 2 upper screws Install the two 2 lower screws and make sure to tighten all screws Enclosure Dimensions pg 13 Secure enclosure to ear...

Page 5: ...les and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates P1MM For use with Multi Mode Fiber for distances up to 550m P1SM10 For use with Single Mode Fiber for distances up to 10km P1AB2K For use with Single Strand Single Mode Fiber for distances up to 2km P1GCE For use with CAT5e or better for distances up to 100m Technical Specifications Parameter Des...

Page 6: ...HTTP Port Enter the HTTP port number assigned to the NetWaySP4 module by the network administrator to allow remote access and monitoring The default inbound port setting is 80 HTTP is not encrypted and unsecure Even though HTTP can be used for remote access it is recommended primarily for use with LAN connections E HTTPS Port Enter the HTTPS port number assigned to the NetWaySP4 module by the netw...

Page 7: ...aded successfully you can proceed with setting up HTTPS in Network Settings A HTTPS Port Enter the HTTPS port number assigned to the NetWay Spectrum module by the network administrator to allow remote access and monitoring The default inbound port setting is 443 Being encrypted and more secure HTTPS is highly recommended for remote access B Click the button labeled Submit Network Settings A dialog...

Page 8: ... ID could be any value 2 4094 6 Assign vLan QOS Quality of Service priority 0 Lowest and 7 Highest 7 Pick a Trunk port Tagged Ports Trunk ports are typically the main connection for network traffic for each group They are usually connected to a network switch WAPs etc 8 Pick the Access port s Untagged Ports associated with the vLan Access Ports are typically used for Cameras etc If programming loc...

Page 9: ...tup Fig 4 Example vLan ID 20 for ports 3 4 Example vLan ID 10 for ports 1 2 NetwaySP4B SFP2 ALOS SFP1 ALOS Trunk i e VLan ID 10 and 20 Pass thru i e VLan ID 10 and or 20 PORT 1 PORT 2 PORT 3 PORT 4 Fiber to Next NetWaySP4 Fiber from Host Switch SFP2 SFP1 ...

Page 10: ...S Input 48V 56VDC PORT 1 PORT 2 PoE3 PoE4 PORT 3 PORT 4 PORT 2 PORT 3 30W 60W 30W 60W SFP Port SFP2 ALOS SFP Port Fiber to the next Netway Spectrum Hardened PoE Switch 30W 60W Operation 5A 250VA DC BAT 115VAC 230VAC 115VAC 230VAC Input Voltage Selection Switch L G N Input Voltage Selection Switch 5A 250VA DC BAT 115VAC 230VAC 115VAC 230VAC L G N 48VDC 300mA to Stand by Batteries Fig 5a Fig 5b Fig ...

Page 11: ...on starting voltage of 56VDC and accounts for a 10 volt drop All distances are per IEEE 802 3at standard for device power requirements of minimum 44VDC and leave an approximate 2 volts for safety and flexibility Fiber to the next Netway Spectrum Hardened PoE Switch Factory Reset PoE1 Altronix Corp Brooklyn NY US www altronix com 10 100 1000 PWR NetwaySP4B PoE2 PORT1 1000 100 PORT3 1000 100 PORT2 P...

Page 12: ...d height of the top Pole Mount bracket is achieved tighten the straps down by sliding open end of the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 9 pg 12 and Fig 10 pg 12 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a...

Page 13: ... 40 35 6mm 1 40 35 6mm 1 40 35 6mm 4 85 123 2mm 4 85 123 2mm 3 25 82 6mm 0 75 19 1mm 0 75 19 1mm 11 0 279 4mm 12 5 317 5mm 1 20 30 5mm 1 20 30 5mm 0 9375 23 8mm 0 9375 23 8mm 5 10 129 5mm 1 40 35 6mm 5 10 129 5mm 6 5625 166 7mm 3 25 82 6mm 3 25 82 6mm 3 25 82 6mm 10 5 266 7mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm 13 0 330 2mm 5 10 129 5mm 1 20 30 5mm ...

Page 14: ...aySP4 Series Installation Guide NetWaySP4PL Mechanical Drawing and Dimensions H x W x D approx 10 75 x 8 875 x 2 375 273 1mm x 225 4mm x 60 3mm 10 75 273 1mm 10 25 260 3mm 8 875 225 4mm 8 25 209 5mm 0 25 6 4mm ...

Page 15: ...D WITH RIVETS Ø 0 375 9 5mm PADLOCK EYE Ø 0 32 8 1mm MOUNTING HOLE TYP 4 PLACES 8 00 203 2mm STAINLESS STEEL PIANO HINGE 10 75 273 1mm 10 00 254mm 8 25 209 6mm 10 25 260 4mm 12 00 304 8mm 13 50 342 9mm 10 32 X 0 25 6 4mm BRASS INSERT X2 1 61 40 9mm 3 96 100 6mm 12 75 323 9mm 11 31 287 3mm 13 31 338 1mm 10 32 X 0 375 9 5mm BRASS INSERT X4 FRONT VIEW FRONT VIEW COVER REMOVED RIGHT SIDE VIEW END VIEW...

Page 16: ...23 310 6mm 17 53 445 3mm 16 00 406 4mm 1 67 42 4mm 5 00 127mm 16 73 425mm 15 3 388 6mm 6 67 169 4mm 4 94 125 5mm 5 77 146 6mm 0 75 19 1mm MOUNTING PLATE Ø 0 32 8 1mm WALL MOUNTING HOLE X 4 NetWaySP4WPX Mechanical Drawing and Dimensions H x W x D approx 17 53 x 15 3 x 6 67 445 3mm x 388 6mm x 169 4mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 US...

Reviews: