Overview:

Altronix NetWay8G, NetWay8GP and NetWay16G Networked Managed Midspans provide PoE/PoE+/Hi PoE 

(up to 60W) power per port, and pass data at 10/100/1000 Mbps at distances up to 100m . Features also include an 

integral battery charger for applications requiring backup and embedded LINQ Technology to monitor, control, 

and report power and diagnostics from anywhere .

Features:

   Installation  Instructions:

Wiring methods shall be in accordance with the National 
Electrical Code (ANSI/NFPA70), local codes, and the au-
thorities having jurisdiction . NetWayG unit is not intended 
to be connected to outside plant leads . These products are 
for indoor use only and must be installed within the pro-
tected premises . If battery bracket is removed, then the unit 
must be installed in a restricted access area (Fig. 1b, pg. 3) .
1 . Attach mounting brackets to NetWayG unit for rack 
  or wall mount installation (Fig. 5 or 6, pg. 8) .
  Affix rubber pads to NetWayG for shelf installation 
  (Fig. 7, pg. 8) .
2 .  Secure the unit in a rack or on a wall, or place unit on a shelf as desired .
 

Note: The following factors should be taken into consideration when installing these rack mount units:

  a .  The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC) .
  b .  Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it .
  c .  When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition .
3 .  Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWayG unit (Fig. 2g, pg. 4) . 
  Plug unit into a reliable earth grounded socket . When using multiple units, the sum of the individual name plate 
  ratings should not exceed the supply circuit rating . 
 

Do not connect to a receptacle controlled by a switch.

4 .  Connect structured cables from port marked [IN] on NetWayG to the corresponding inputs of an ethernet 
  switch or video server (Fig. 2b, pg. 4, Fig. 4, pg. 6) .
 

Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application .

5 .  Connect structured cables from port marked [OUT] on NetWayG to PoE compliant camera/edge devices 
  (Fig. 2a, pg. 4, Fig. 3, pg. 5) . 
6 .  When the use of stand-by batteries is required, they must be sealed lead acid or gel type . Connect four (4) 
  12VDC batteries in series to terminals marked [+ BAT –] (Fig. 2h, pg. 4), carefully observing polarity .
 

Note: When batteries are not used a loss of AC will result in a loss of output voltage .

Agency Listings:

• 

UL 60950-1 

Information Technology

  

Equipment . 

• 

CE  

European Conformity .

Input:

 NetWay8G: 

115VAC, 60Hz, 3 .25A or 

   

230VAC, 50/60Hz, 2 .0A .

 NetWay8GP/16G:  115VAC, 60Hz, 5 .5A or 

   

230VAC, 50/60Hz, 3 .0A .

Power:

•  Unit supplies PoE output voltage (55V) .

  Total power: 

  NetWay8G (up to 30W per port): 

240W .

  NetWay8GP (up to 60W per port): 

480W .

  NetWay16G (up to 30W per port): 

480W .

•  IEEE 802 .3af and IEEE 802 .3at compliant

 (PoE/PoE+/60W) .

•  Short circuit protection .

Ethernet:

•  Eight (8) or sixteen (16) ports for 

  cameras/edge devices over ethernet .

•  Wire type: 4-pair CAT5e and higher .

• Speed: 10/100/1000 Mbps .

Functions:

•  Auto detection and protection of legacy non-PoE 

  cameras/edge devices .

Battery Backup:

•  Built-in battery charger (optional rack mount 

  battery enclosure - RE2) .

•  Automatic switchover to stand-by battery when 

  AC fails . 

LINQ Technology:

•  SSL (Secure Socket Layer) security encryption .

•  User level security .

•  Built-in IP management allows for remote camera 

  reset and monitoring .

•  Provides local and/or remote access to critical 

  information via LAN/WAN

•  Email and Windows Dashboard Alert notifications 

  report real-time diagnostics .

•  Event log tracks history .

Accessories:

NetWayXT:

•  PoE repeater module extends data range 100m .

NetWayXTX:

•  PoE/PoE+ repeater module extends data range 100m .

RE2:

•  Rack Mount Battery Enclosure accommodates up 
  to four (4) 12VDC/7AH batteries

Fig. 1a 

Fig. 1b

Summary of Contents for NetWay8G

Page 1: ...Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include NetWay8G Eight 8 Port PoE Midspan Injector 240W total power NetWay8GP 8 Port Managed Hi PoE Midspan Injector 480W total power NetWay16G Sixteen 16 Port PoE Midspan Injector 480W total power ...

Page 2: ...tWayXT NetWayXTX Repeater Module pg 5 Port LED Definitions for NetWayXT and NetWayXTX Repeaters pg 5 NetWayG Typical Applications pg 6 Technical Specifications pg 6 Configuring NetWayG for Network Connection Factory Default Settings pg 6 Network Settings pg 6 Static pg 6 DHCP pg 7 Secure Network Setup HTTPS pg 7 Mounting Options pg 8 ...

Page 3: ...y a switch 4 Connect structured cables from port marked IN on NetWayG to the corresponding inputs of an ethernet switch or video server Fig 2b pg 4 Fig 4 pg 6 Note All cabling and wire must be UL Listed and or Recognized wire suitable for their application 5 Connect structured cables from port marked OUT on NetWayG to PoE compliant camera edge devices Fig 2a pg 4 Fig 3 pg 5 6 When the use of stand...

Page 4: ... Sixteen 16 PoE PoE Ports 10 100 1000 Mbps Input Power Requirements NetWay8G 115VAC 60Hz 3 25A or 230VAC 50 60Hz 2 0A NetWay8GP 115VAC 60Hz 5 5A or 230VAC 50 60Hz 3 0A NetWay16G 115VAC 60Hz 5 5A or 230VAC 50 60Hz 3 0A Indicators Port Status LEDs Environmental Conditions Operating Ambient Temperature 20ºC to 50ºC 4ºF to 122ºF Relative Humidity 85 5 Storage Temperature 20ºC to 70ºC 4ºF to 158ºF Oper...

Page 5: ...tes no link Indicates no link ON Normal PoE PoE Output Indicates 1G link Indicates 10 100 link Blinking Indicates 1G activity Indicates 10 100 activity The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric sh...

Page 6: ...n labeled Log In 4 The status page of the NetWayG will appear Click on the tab labeled Network Settings This will open the Network Setting screen In this screen the MAC Address of the NetWayG module will be found along with the Network Settings and Email Settings Network Settings In the IP Address Method field select the method that the IP Address for the NetWayG will be obtained STATIC or DHCP th...

Page 7: ...ions Secure Network Setup HTTPS In order to setup HTTPS for a Secure Network Connection a Valid Certificate and Key must be used Certificates and Key should be in a PEM format Self Certifications should only be used for testing purposes as no actual authentication is being performed In a Self Certified mode the connection will still state that it is unsecure How to upload Certificate and Key to se...

Page 8: ...A B Fig 5b Fig 5a Fig 5 Fig 5c Top Top Top Front Left Front Left Front Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using four 4 flat head screws B included Fig 6a 2 Place unit at desired location and secure with 6 size screws or larger not included Fig 6b Caution It is necessary to make sure mounting screws are securely fastened to a...

Reviews: