Overview:

Altronix NetWay8MV/NetWay16MV Managed Midspans provide power and pass data for PoE compliant cam-
eras/edge devices . Cameras/edge devices may be located up to 100m from the NetWayMV unit . A NetWayXT/
NetWayXTX repeater module can be utilized to extend the distance an additional 100m for a total range of up to 
200m . A maximum range of 600m is possible using multiple repeaters, based on camera/device port requirement . 
NetWay Managed Midspans are capable of supporting non-PoE compliant fixed and PTZ IP cameras utilizing 
NetWay1512 or NetWay3012 adapters .

NetWayMV Specifications:

Common Specifications:

NetWay8MV:

•  Eight (8) ports of cameras/edge devices over ethernet 
  (CAT5) cable up to a distance of 100m per port .
•  220VAC 60Hz, 1 .5A (NetWay8MV) .

NetWay16MV:

•  Sixteen (16) ports of cameras/edge devices over 
  ethernet (CAT5) cable up to a distance of 100m 
  per port .
•  220VAC 60Hz, 2 .5A (NetWay16MV) .

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the 
authorities having jurisdiction . NetWayMV is not intended to be connected to outside plant leads . These products 
are for indoor use only and must be installed within the protected premises .
1 . Attach mounting brackets to NetWayMV unit for rack or wall mount installation (Figs. 8 or 9, pg. 12) .
  Affix rubber pads to NetWayMV for shelf installation (Fig. 10, pg. 12) .
2 .  Secure the unit in a rack or place unit on a shelf as desired .
 

Note: The following factors should be taken into consideration when installing these rack mount units:

  a . The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC) .
  b . Take care to ensure there is sufficient air flow around the unit and that obstructions do not impede it .
  c . When mounting units in rack, take care to avoid uneven loading which can cause a hazardous condition .
3 .  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1g, pg. 4) .
4 .  Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWayMV unit (Fig. 1h, pg. 4) . 
  Plug unit into a reliable earth grounded socket . When using multiple units, the sum of the individual name 
  plate ratings should not exceed the supply circuit rating . 

Do not connect to a receptacle controlled by a switch.

5 .  Connect structured cables from port marked [IN] on NetWayMV to the corresponding inputs of an ethernet 
  switch or video server (Fig. 1b, pg. 4, Fig. 5, pg. 6) .
 

Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application .

6 .  Connect structured cables from port marked [OUT] on NetWayMV to PoE compliant camera/edge devices
  (Fig. 1a, pg. 4, Fig. 5, pg. 6) . 
7 .  Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) 
 position 

(Fig. 1g, pg. 4) .

Agency Listings:

• 

CE  

European Conformity .

Power:

•  Unit supplies PoE output voltage (55V), and up to 
  30W max . full power per port .
 

Total power: 

NetWay8MV - 150W,

     

NetWay16MV - 300W .

•  IEEE 802 .3af and IEEE 802 .3at compliant 
  (PoE Plus) .
•  All output circuits are power-limited .
•  Short circuit protection .

Functions:

•  Programmble PoE shutdown for each port . 
  Utilized to reset cameras/edge devices
  (see Technical Specifications pg. 5).
•  PoE manual shutdown (See Technical 
  Specifications, pg. 5
) .
•  Auto detection and protection of legacy
  non-PoE cameras/edge devices .

Features:

•  LAN or laptop connection enables programming of 
  PoE shutdown and port monitoring .
•  User interface (Fig. 6, pg. 8) .
•  Illuminated master power disconnect circuit 
  breaker with manual reset (switch) .
•  Individual port status LEDs .
•  IEC 320 - 3-wire grounded line cord (detachable) .
•  Unit can be rack or shelf mounted .
•  1U rack mount chassis for use in standard 
  EIA 19” rack .

Accessories:

NetWay1512:

•  15W adapter for non-PoE compliant IP cameras .

NetWay3012:

•  25W adapter for non-PoE compliant IP 
  fixed or PTZ cameras .

NetWayXT:

•  PoE repeater module extends range 100m

NetWayXTX:

•  PoE+ repeater module extends range 100m .

Summary of Contents for NetWay16MV

Page 1: ...TMV Rev 050611 Power over the Ethernet PoE Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include NetWay8MV Eight 8 Port PoE Midspan Injector NetWay16MV Sixteen...

Page 2: ...ort LED Definitions for NetWayXT Repeater pg 5 Port LED Definitions for NetWayXTX Repeater pg 5 Typical Application pg 6 Technical Specifications pg 6 NetWay8MV NetWay16MV User Interface and Programmi...

Page 3: ...cause a hazardous condition 3 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1g pg 4 4 Plug the grounded AC line cord included into the IEC 320 connector of the NetWay...

Page 4: ...s Description All Ports Off Sequential LED Port Scan No devices connected Port Off OFF LED OFF Port On ON LED ON Class 4 detection Port Blinks 2 times Enables power to PoE devices Non compliant Device...

Page 5: ...zing the mounting hole Fig 4 pg 5 Use a proper fastener and or wall anchor when securing NetWayXT NetWayXTX to the wall 2 Connect structured cable from port marked OUT on NetWay to port marked IN on t...

Page 6: ...tWay8MV Eight 8 Ports NetWay16MV Sixteen 16 Ports Input Power Requirements NetWay8MV 220VAC 60Hz 1 5A NetWay16MV 220VAC 60Hz 2 5A Fuse 4A 125V NetWay16MV has 2 fuses Note To reduce the risk of fire re...

Page 7: ...he Networking tab Under this connection uses the following items click either Internet Protocol Version 4 TCP IPv4 and then click Properties d Choose the Use the following IP address option e Set the...

Page 8: ...lick on the Enable radio button s in the PoE shutdown column Fig 6 pg 10 2 To disable PoE shutdown for one or more ports click on the Disable radio button s in the PoE shutdown column Fig 6 pg 10 Note...

Page 9: ...the LAN Additional information 1 If using DHCP all settings will be detected automatically While DHCP is a useful tool for determining the network settings if you set up your NetWay8MV Net Way16MV in...

Page 10: ...t by choosing a port commonly used for another purpose like port 25 for SMTP mail or port 448 for secure sockets choose an unusual port number For example add 50 000 to your house number 50 123 is les...

Page 11: ...ert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equila...

Page 12: ...uded Fig 8c A B Fig 8b Fig 8a Fig 8 Fig 8c Top Top Top Front Left Front Left Front Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using fo...

Reviews: