NetWay112 Port Status and LED Flash Codes

Port Status

Flash Code

Flash Pattern

Non-Powered Device 0

Ω

 < 

R

PORT < 200

Ω

OFF

LED OFF

Port Open 

R

PORT > 1M

Ω

OFF

LED OFF

Port On 25k

Ω

ON

LED ON

Low Signature Resistance 300

Ω

 < 

R

PORT < 15k

Ω

1 Flash

Z

  

 

l l l

 

Z

 

 

 

l l l

 

Z

  

 

l l l

High Signature Resistance 33K

Ω

 < 

R

PORT < 500k

Ω

2 Flashes

Z Z

 

 

 

l l

 

Z Z

  

 

l l

 

Z Z

 

 

 

l l

Port Overload Fault

5 Flashes

 

 

l l l l

 

Z Z

 

Z Z Z

  

 

l l l l

Installing NetWayXT repeater module:
1. Mount NetWayXT in desired location utilizing the mounting hole (Fig. 4, pg. 3).  Use a proper fastener and/or wall 

  anchor when securing NetWayXT to the wall.
2. Connect structured cable from port marked [OUT] on NetWay112 to port marked [IN] on the 
  NetWayXT (Fig. 4, pg. 3, Fig. 1b pg. 2)
3. Connect structured cable from port marked [OUT] on NetWayXT to the PoE camera/device or next NetWayXT
 repeater 

(Fig. 4, pg. 3).

4. Port status LEDs will illuminate on NetWayXT indicating the port is operational (Fig. 4, pg. 3,
  refer to Port LED definitions on pg. 2)
.

Port LED definitions for NetWayXT repeater:  

Status

Green LED

Yellow LED

OFF

Indicates it is connected as 10Base-T or no link.

Indicates no link.

ON

Indicates it is connected as 100Base-T.

Indicates a link.

Blinking

-------

Indicates activity.

Structured

Cable from

Network

Switch

12VDC

Input

+   ---

12VAC to 24VAC or

5VDC to 24VDC Input

for PoE shutdown

Structured Cable from

IP Camera, IP Lock or IP device,

NetWay1512 or NetWayXT

+ 12VDC ---

Input

Power

Shutdown

IN

OUT

Port

Status

NetWay112

Single Port Injector (Midspan)

12VDC, 1.6A Input
48VDC 15.4W max. per IEEE 802.3af

www.altronix.com

Fig. 1b

Fig. 1a

Structured

Cable from

Network

Switch

24VAC/

24VDC Input

12VAC to 24VAC or

5VDC to 24VDC Input

for PoE shutdown

Structured Cable from

IP Camera, IP Lock or IP device,

NetWay1512 or NetWayXT

24VAC/VDC

Input

Power

Shutdown

IN

OUT

Port

Status

General Signaling

Equipment 92R2

I.T.E. 43KC

NetWay1

Single Port Injector (Midspan)

24VAC/VDC, 1.2A Input
48VDC 15.4W max. per IEEE 802.3af

www.altronix.com

Equipment 92R2

Access Control PoE Injector

Attack Class 

I

 

Fig. 1c

Fig. 1

Reviews: