Altronix HubWay ld Installation Manual Download Page 3

 

HubWayLD Active Isolated Unit 

- 3 -

3.  Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3”    

 

from any video monitors).

4.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).

5.  Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8Di/HubWayLD16Di

 unit 

(Fig. 1j, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.

6.  Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).

7.  Connect the BNC video outputs for HubWayLD8Di/LD16Di Channels 1 - 8 (Channels 1-16) to the

 

corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).

8.  Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal 

 

blocks of the HubWayLD8Di or HubWayLD16Di unit (polarity must be observed) (Fig. 1e, pg. 4)

 

Note: The Data input terminals of the HubWayLD8Di or HubWayLD16Di must be wired in parallel for proper

 

operation. When using fixed cameras disregard this step.

9.  Connect Video Balun/Combiner at camera 1 to the HubWayLD8Di or HubWayLD16Di unit utilizing CAT-5 or 

 

higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked  

 

 

[Channel 1] of the HubWayLD8Di/LD16Di (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the 

 

structured cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 5).

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

•  For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).

 

Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16).

 

Note: When a particular camera exceeds the maximum distance for power transmi  ssion, a local external power 

 

source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power 

 

may be utilized (Fig. 4a, pg. 6).

 

The combined total cable distance must not exceed 3000 ft. for video transmission between the 

 

HubWayLD8D i/LD16Di and each camera routed through the HubSat4D.

10.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the

 

output voltage at the power output of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera 

 

to ensure proper operation and avoid possible damage.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

11.  Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections

 

(Fig. 5, pg. 7).

12.  Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to  

 

the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed.

13.  Connect the terminals marked [+ DATA -- ] of the HubWayAv or HubWayDv Video Balun/Combiners to the data

 

terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity must be observed.

 

When using fixed cameras disregard this step.

14.  Connect the BNC connector of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners   

 

to the BNC video outputs of the cameras (Figs. 2a-2e, pg. 5).

15.  Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position

 

(Fig. 5, pg. 7). 

16.  The power LEDs (Red) located on the front of the HubWayLD8Di/LD16Di will illuminate when AC power 

 

is present (Fig. 1c, pg. 4).

 

Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the 

 

PTC is tripped for that channel.

 

To reset the PTC:

 

1.  Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain

 

 

in the OFF position for approximately 2 minutes in order for the PTC to reset.

 

2.  Eliminate the trouble condition (short circuit or overload).

 

3.  Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1d, pg. 4).

17.  AC LED (Green) of the HubWayAv or DC LED (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners  

 

 

will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 

18.  The video signal indicator LEDs (Red) located on the rear of the HubWayLD8Di /LD16Di will illuminate when 

 

video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present for 

 

that corresponding channel.

19.  Optimize the picture quality for Channels 1-8 (Channels 1-16)  by adjusting the corresponding potentiometers 

 

marked [Picture] (Fig. 1g, pg. 4).

20.  Set gain for Channels 1-8 or Channels 1-16 by adjusting the corresponding potentiometers marked [Gain]

 

(Fig. 1h, pg. 4).

Summary of Contents for HubWay ld

Page 1: ...ceiver Hub with Integral Isolated Camera Power Transceiver Hub with Integral Isolated Camera Power Includes eight 8 UL Listed Accessory Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayAv Video Balun Combiners HubWayLD83Di HubWayLD163Di UL Listed eight 8 Channel Active UTP UL Listed sixteen 16 Channel Active UTP Transceiver Hub with Integral Isolated Camera Power Transc...

Page 2: ...yLD8Di with eight 8 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras HubWayLD162Di HubWayLD16Di with sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWayLD163Di HubWayLD16Di with sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras Agency Listings UL Listed for Commercial CCTV Equipment UL 2044 CUL Listed CSA Standard...

Page 3: ...nect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output of each Video Balun Combiner Figs 2b 2d pg 5 before powering each camera to ensure proper operation and avoid possible damage HubWayAv HubWayAv2 Terminals marked AC POWER Figs 2a 2b 2e pg 5 HubWayDv HubWayDvi Terminals marked 12VDC Figs 2c 2d pg 5 11 Set illuminated master power disconnect c...

Page 4: ... data trans mission to PTZ s 1f BNC Connector Video outputs to head end equipment DVR 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1i LED s 1 16 Video signal indicators 1j IEC 320 Connector 115VAC 60Hz 230VAC 50...

Page 5: ...or Codes and PIN Configurations HubWayAv HubWayAv2 passes AC voltage from pins 4 5 7 8 to terminals marked AC Power Fig 3 pg 5 HubWayDv HubWayDvi converts AC voltage to DC voltage from pins 4 5 7 8 to terminals marked 12VDC Fig 3 pg 5 VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wir...

Page 6: ...Video Balun Combiner HubWayAv Video Balun Combiner Fixed Camera Fixed Camera Max video 3000 ft PTZ Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA...

Page 7: ...ped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user ...

Page 8: ...o a beam when installing the unit vertically Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 6a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 6b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 6c Fig 8 Fig 7 Shelf Inst...