7.  Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] 
 

on Circuit Board A (Fig. 1i, pg. 5). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured 

 

cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 6).

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).

 

The total cable distance must not exceed 750 ft. for video transmission between the HubSat8D and each camera.

 

Repeat this step for all other camera channels [PVD2-4] on Circuit Board A and [PVD1-4] on Circuit Board B.

8.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 3a, pg. 6). Power 
 

LEDs (Green) of the HubSat8Di will illuminate when AC power is present (Fig. 1e, pg. 5) and HubWayAv or

 

HubWayDv Video Balun/Combiner LEDs will illuminate, indicating power is present (Fig. 2b, 2d, pg. 6).

9.  Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to
 

each camera to ensure proper operation and avoid possible damage.

10.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3a, pg. 6).
11.  Connect power outputs of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners to power inputs
 

of cameras (Figs. 2a-2e, pg. 6). Polarity must be observed.

  • HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 6).
 

•  HubWayDv - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 6).

12.  Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners to   
 

the data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed.

 

When using fixed cameras disregard this step.

13.  Connect the BNC connector of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners to the BNC video   
 

outputs of the cameras (Figs. 2b-2d, pg. 6).

14.  Set illuminated master power disconnect circuit breaker to the RESET [ON] position (Fig. 3a, pg. 6).
15.  The power LEDs (Green) of the HubSat8Di will illuminate when AC power is present (Fig. 1e, pg. 5).  
 

Note: If any of the power LEDs are not illuminated the cause may be due to the following:

 

a.  AC mains fail.

 

b.  Illuminated master power disconnect circuit breaker is tripped.

 

c.  An individual power output voltage switch is set to the OFF position (Fig. 1d, pg. 5).

 

d.  A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

 

 

To reset the PTC:

 

 

1.  Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must 

 

 

 

remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 1d, pg. 5).

 

 

2.  Eliminate the trouble condition (short circuit or overload).

 

 

3.  Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 1d, pg. 5).

HubSat8Di for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.
After completing steps 1-4 of Installation Instructions for HubSat8Di Passive UTP Transceiver Hub with Integral Camera 
Power proceed with the following.
1.  For fixed cameras, run two (2) CAT-5 cables between HubSat8Di and HubWay, HubWayLD or HubWayLDH to allow
 

video transmission of up to eight (8) cameras. For PTZs, run three (3) CAT-5 cables between HubSat8Di and

 

HubWay, HubWayLD or HubWayLDH (Fig. 5, pg. 7).

 

a.  Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on Circuit Board A. Connect the

 

 

opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or

  HubWayLDH 

unit 

(Fig. 5, pg. 7).

 

b.  Connect the second CAT-5 cable to the RJ45 jack marked [Video 1-4] on Circuit Board B. Connect the

 

 

opposite end of this CAT-5 cable into the RJ45 jack marked [CH 5-8] of HubWay, HubWayLD or

  HubWayLDH 

unit 

(Fig. 5, pg. 7).

 

c.  For data (PTZ) connect the third CAT-5 cable to the RJ45 jack marked [Data 1-4] on Circuit Board A. Connect 

 

 

the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or

  HubWayLDH 

unit 

(Fig. 5, pg. 7).

 

Note: Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper operation.

 

When using fixed cameras disregard this step.

2.  Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1] 
 

on Circuit Board A (Fig. 1i, pg. 5). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured    

 

cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 6).

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 6).

Summary of Contents for HubSat8Di

Page 1: ...annel Passive UTP Transceiver Hub with Integral Camera Isolated Power HubSat82Di Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayAv Video Balun Combiners HubSat83Di Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayDv Video Balun Combiners Rev 032910 More than just power TM Video Data Power ...

Page 2: ...ith eight 8 HubWayDv Video Balun Combiners for 12VDC Cameras WARNING To reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes Installation Instructions HubSat8Di Passive UTP Transceiver Hub with Integral Isolated Camera Power 1 Mount unit in the desired location Mark...

Page 3: ...l b Illuminated master power disconnect circuit breaker is tripped c An individual power output voltage switch is set to the OFF position Fig 1d pg 5 d A PTC is tripped due to a short circuit or overload condition for one or more channels power outputs To reset the PTC 1 Set the voltage output selector switch for that corresponding channel to the OFF position Switch must remain in the OFF position...

Page 4: ...he power LEDs Green of the HubSat8Di will illuminate when AC power is present Fig 1e pg 5 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c An individual power output voltage switch is set to the OFF position Fig 1d pg 5 e A PTC is tripped due to a short circuit or overload cond...

Page 5: ...ble out to HubWay HubWayLD or HubWayLDH enables transmission of up to four 4 video signals 1h Data CAT 5 or higher structured cable to data port on HubWay HubWayLD or HubWayLDH or head end equipment DVR 1i Channels 1 4 CAT 5 or higher structured cable to cameras 1a 1i 1b 1c 1d 1e 1f 1g 1h 1c 1 White Orange VIDEO 2 Orange VIDEO 3 White Green DATA 4 Blue AC 1 5 White Blue AC 2 6 Green DATA 7 White B...

Page 6: ...en Lead ground XFMR Black Lead Wire Strap from Enclosure to Door XFMR non power limited PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3 PVD4 DATA DATA 1 4 VIDEO 1 4 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC OFF OFF OFF OFF AUX1 AUX2 AUX3 AUX4 non power limited PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3 PVD4 DATA DATA 1 4 VIDEO 1 4 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC OFF OFF OFF OFF AU...

Page 7: ...Video Data Power Video Data Power 12VDC PTZ Camera Coax Power 12VDC Fixed Camera Coax Power HubWayD Video Balun Combiner Video Data Power 12VDC PTZ Camera 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Fig 5 Typical Application Drawing HubSat8Di Passive UTP Transceiver Hub with Integral Camera Power 115VAC Input 60Hz Head End Equipment DVR RS485 BNC Data Video Power...

Page 8: ...thin an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm...