Altronix HubSat8D Installation Manual Download Page 5

HubSat8D

- 5 -

10. The power LEDs (Green) of the HubSat8D will illuminate when AC power is present 

(Fig. 1e, pg. 4).

Note:

If any of the power LEDs are not illuminated the cause may be due to the following:

a.

AC mains fail.

b.

Illuminated master power disconnect circuit breaker is tripped.

c.

One or both primary in-line fuse(s) are blown.

Note: Replace fuse with same type and rating:

Primary in-line fuses are rated @ 3.5A/250V 

(Fig. 4b, pg. 6)

.

d. An individual power output voltage switch is set to the OFF position 

(Fig. 1d, pg. 4)

.

e.

A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.
To reset the PTC:
1.

Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must 
remain in the OFF position for approximately 2 minutes in order for the PTC to reset 

(Fig. 1d, pg. 4)

.

2.

Eliminate the trouble condition (short circuit or overload).

3.

Set the voltage output selector switch for either 24VAC or 28VAC 

(Fig. 1d, pg. 4)

.

Alternate 24VAC fixed camera hookup 

(Fig. 6a, pg. 7)

.

After completing steps 1-5 of Installation Instructions Remote Accessory Module for use with HubWay, HubWayLD or
HubWayLDH UTP Transceiver Hubs proceed with the following.
1. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 4a, pg. 6)

2. Connect one end of the coaxial cable to the BNC connector marked [Video1] on Circuit Board A 

(Fig. 1a, pg. 4)

Connect the opposite end of the coaxial cable to the BNC video output of camera 1 

(Fig. 6a, pg. 7)

.

3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position 

(Fig. 4a, pg. 6) 

measure the 

output voltage at terminal pair marked [AUX1] on Circuit Board A to insure proper operation and 
avoid possible damage 

(Fig. 1b, pg. 4)

.

4. Connect the power output terminal pair marked [AUX1] on Circuit Board A to the power inputs of camera 1

(Fig. 1c, pg. 4)

. Repeat steps 1-3 for each additional camera [AUX2-4].

Primary
In-line Fuse

HubWayAv, HubWayDv and HubWayDvi Video Balun/Combiners:

HubWayAv

*24VAC/28VAC   *24VAC/28VAC

24VAC cameras

Green

HubWayDv

*24VAC/28VAC     12VDC

12VDC cameras

Red

HubWayDvi

*24VAC/28VAC  12VDC electronically isolated

12VDC cameras without isolation

Red

Altronix 
Model
Number

Output

 V

oltage  

to camera

Input 

V

oltage 

from HubW

ay

unit

Camera 

Type

Po

w

er LED

*Based on camera load and structured cable length.

Summary of Contents for HubSat8D

Page 1: ...hannel Passive UTP Transceiver Hub with Integral Camera Power HubSat82D Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayAv Video Balun Combiners HubSat83D Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayDv Video Balun Combiners Rev 112508 More than just power TM Video Data Power ...

Page 2: ...at82D HubSat8D with eight 8 HubWayAv Video Balun Combiners for 24VAC Cameras HubSat83D HubSat8D with eight 8 HubWayDv Video Balun Combiners for 12VDC Cameras WARNING To reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes Installation Instructions HubSat8D Passive U...

Page 3: ...pg 6 15 The power LEDs Green of the HubSat8D will illuminate when AC power is present Fig 1e pg 4 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c One or both primary in line fuse s are blown Note Replace fuse with same type and rating Primary in line fuses are rated 3 5A 250V ...

Page 4: ...s of HubWayAv HubWayDv or HubWayDvi Video Balun Combiners to power inputs of cameras Figs 2a 2d pg 6 Polarity must be observed HubWayAv Terminals marked AC POWER Figs 2a 2b pg 6 HubWayDv HubWayDvi Terminals marked 12VDC Figs 2c 2d pg 6 7 Connect the terminals marked DATA of HubWayAv HubWayDv or HubWayDvi Video Balun Combiners to data input terminals of cameras for PTZ control Figs 2b 2d pg 6 Polar...

Page 5: ...Remote Accessory Module for use with HubWay HubWayLD or HubWayLDH UTP Transceiver Hubs proceed with the following 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 4a pg 6 2 Connect one end of the coaxial cable to the BNC connector marked Video1 on Circuit Board A Fig 1a pg 4 Connect the opposite end of the coaxial cable to the BNC video output of camera 1 Fig 6a pg...

Page 6: ...erts AC voltage to DC voltage through pins 4 5 7 8 and 12VDC terminals 115VAC input 60 Hz White Lead Green Lead ground XFMR Black Lead Wire Strap from Enclosure to Door XFMR Primary In line Fuse non power limited PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3 PVD4 DATA DATA 1 4 VIDEO 1 4 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC 24VAC OFF OFF OFF OFF AUX1 AUX2 BK 24 YL 0 Br AUX3 AUX4 non power limited...

Page 7: ...Video Data Power Video Data Power 12VDC PTZ Camera Coax Power 12VDC Fixed Camera Coax Power HubWayD Video Balun Combiner Video Data Power 12VDC PTZ Camera 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Coax Power 24VAC Fixed Camera Fig 6 Typical Application Drawing HubSat8D Passive UTP Transceiver Hub with Integral Camera Power 115VAC Input 60Hz Head End Equipment DVR RS485 BNC Data Video Power ...

Page 8: ...s 13 5 H x 13 W x 3 25 D The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating a...

Reviews: