3.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6) power 

 

LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4) and HubWayAv, HubWayDv

 

or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 2b, 2d, pg. 6).

4.  Measure the output voltage at each Video Balun/Combiner (Figs. 2b, 2d, pg. 6) before making connections to

 

each camera to insure proper operation and avoid possible damage.

5.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5a, pg. 6).

6.  Connect power outputs of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to power   

 

inputs of cameras (Figs. 2a-2e, pg. 5-6). Polarity must be observed.

  • HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5-6).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).

7.  Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video  

 

 

Balun/Combiners to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 5). Polarity must be observed.

 

When using fixed cameras disregard this step.

8.  Connect the BNC connector of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to    

 

the BNC video outputs of cameras (Figs. 2a-2e, pg. 5-6).

9.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6).

10.  The power LEDs (Green) of the HubSat will illuminate when AC power is present (Fig. 1e, pg. 4).  

 

Note: If any of the power LEDs are not illuminated the cause may be due to the following:

 

a.  AC mains fail.

 

b.  Illuminated master power disconnect circuit breaker is tripped.

 

c.  One or both primary in-line fuse(s) are blown.

 

 

Note: Replace fuse with same type and rating:

 

 

Primary in-line fuses are rated @ 3.5A/250V (Fig. 5b, pg. 6).

 

d.  An individual power output voltage switch is set to the OFF position (Fig. 1d, pg. 4).

 

e.  A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

 

 

To reset the PTC:

Fig. 1 - HubSat Circuit Board

PVD1

VIDEO1

VIDEO2

VIDEO3

VIDEO4

PVD2

PVD3

PVD4

+ DA

TA

 -

DATA 1-4

VIDEO 1-4

28VAC

24VAC

28VAC

24VAC

28VAC

24VAC

28VAC

24VAC

OF

F

OF

F

OF

F

OF

F

AUX1

AUX2

AUX3

AUX4

1a - 

BNC Connector: Video in from remote camera

video out to DVR.
1b - 

Output PTCs: Protects each output.

1c - 

Power Terminals: 24VAC/28VAC power outputs.

1d - 

Output Voltage Switches: Selects 24VAC/28VAC/

OFF for each output.
1e - 

LED(s) 1-4: Power output indicators.

1f - 

Data: RS422/RS485 input from head end equipment 

(DVR) for PTZ control.

1g - 

Channels 1-4: Single CAT-5 or higher structured 

cable out to HubWay, HubWayLD or HubWayLDH 
enables transmission of up to  four (4) video signals.
Pin out configuration (Fig. 4, pg. 6).
1h - 

Data: CAT-5 or higher structured cable to data port

on HubWay, HubWayLD or HubWayLDH or head end 
equipment (DVR).
1i - 

Channels 1-4: CAT-5 or higher structured cable

to cameras. Pin out configuration (Fig. 3, pg. 6).

1a

1i

1b

1c

1d

1e

1f

1g

1h

1c

Primary
In-line Fuse

Summary of Contents for HubSat4D

Page 1: ...Channel Passive UTP Transceiver Hub with Integral Camera Power HubSat42D Four 4 Channel Passive UTP Transceiver includes four 4 HubWayAv Video Balun Combiners HubSat43D Four 4 Channel Passive UTP Transceiver includes four 4 HubWayDv Video Balun Combiners Rev 112408 More than just power TM Video Data Power ...

Page 2: ...D with four 4 HubWayAv Video Balun Combiners for 24VAC Cameras HubSat43D HubSat4D with four 4 HubWayDv Video Balun Combiners for 12VDC Cameras WARNING To reduce the risk of fire or electric shock do not expose the unit to rain or moisture This installation should be made by qualified service personnel and should conform to all local codes Installation Instructions HubSat4D Passive UTP Transceiver ...

Page 3: ...g 5b pg 6 d An individual power output voltage switch is set to the OFF position Fig 1d pg 4 e A PTC is tripped due to a short circuit or overload condition for one or more channels power outputs To reset the PTC 1 Set the voltage output selector switch for that corresponding channel to the OFF position Switch must remain in the OFF position for approximately 2 minutes in order for the PTC to rese...

Page 4: ...10 The power LEDs Green of the HubSat will illuminate when AC power is present Fig 1e pg 4 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c One or both primary in line fuse s are blown Note Replace fuse with same type and rating Primary in line fuses are rated 3 5A 250V Fig 5b ...

Page 5: ...1 3 for each additional camera AUX2 4 HubWayAv HubWayAv2 HubWayDv and HubWayDvi Video Balun Combiners Altronix Model Number Input Voltage from HubWay Unit Output Voltage to Camera Camera Type Power LED HubWayAv 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC Green HubWayAv2 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC N A HubWayDv 24VAC 28VAC 12VDC 12VDC cameras Red HubWayDvi 24VAC 28VAC 12VDC electronically isolated ...

Page 6: ...illuminated RESET ON position Switch illuminated Fig 5a Fig 5b Primary In line fuse Rated 3 5A 250V 1 White Orange VIDEO 2 Orange VIDEO 3 White Green DATA 4 Blue AC 1 5 White Blue AC 2 6 Green DATA 7 White Brown AC 2 8 Brown AC 1 Fig 3 CAT 5 Structured Cable Wiring Color Codes and PIN Configurations PVD1 4 on HubSat4D and Video Balun Combiner Fig 4 CAT 5 Structured Cable Wiring Color Codes for Vid...

Page 7: ... 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat4D 115VAC Input 60Hz 24VAC Fixed Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 CAT 5 CAT 5 12VDC Fix...

Page 8: ...thin an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel Enclosure Dimensions H x W x D approximate 8 5 x 7 5 x 3 5 21...