Altronix HubSat42WPV Installation Manual Download Page 7

 

HubSat4WPV 

- 7 -

HubWayAv, HubWayAv2, HubWayDv, and HubWayDvi

Video Balun/Combiners:

Altronix 
Model
Number

Input Voltage 

from 

HubWay Unit

Output Voltage to Camera

Camera Type

Power 

LED

HubWayAv

*24VAC/28VAC 

*24VAC/28VAC

*24VAC/28VAC

Green

HubWayAv2

*24VAC/28VAC

*24VAC/28VAC

*24VAC/28VAC

N/A

HubWayDv

*24VAC/28VAC

12VDC

12VDC cameras

Red

HubWayDvi

*24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolation

Red

*Based on camera load and structured cable length .

VIDEO BALUN/COMBINER

             CAT5          + DATA-- POWER

AC

VIDEO

HubWayAv

VIDEO

AC Power

to Camera

Data to

Camera

--
+

Data to

Camera

Green Power LED

12VDC Power

to Camera

+
--

Red Power LED

Wire 

Connectors

RJ45 Jack

RJ45 Jack

To BNC

Connector

of Camera

To BNC

Connector

of Camera

Structured

Cable from

HubWay8CD

or

HubWay16CD

Structured

Cable from

HubWay8CD

or

HubWay16CD

VIDEO BALUN/COMBINER

HubWayDv

             CAT5             + DATA--  -- 12VDC+

--
+

Wire 

Connectors

* Also Available as:
 

HubWayDvi

 

 Video Balun/

 Combiner 

  for non-isolated

  12VDC cameras

Fig. 3

Fig. 3a

Fig. 3c

Fig. 3b

Fig. 3d

Fig. 3e 

HubWayAV2

Video from Camera

Data to Camera

Power to Camera

Cat5

back to

HubWay

or

HubSat

 HubWayAv/HubWayAv2 passes AC voltage from 
pins 4, 5, 7, 8 to terminals marked [AC Power]
(Fig. 4, pg. 8) .

HubWayDv/HubWayDvi converts AC voltage to DC 
voltage from pins 4, 5, 7, 8 to terminals marked 
[– 12VDC +] (Fig. 4, pg. 8) .

1 - White/Orange [VIDEO +]
2 - Orange [VIDEO -- ]
3 - White/Green [DATA +]
4 - Blue [AC 1]
5 - White/Blue [AC 2]
6 - Green [DATA -- ]
7 - White/Brown [AC 2]
8 - Brown [AC 1]

CAT-5 Structured Cable Wiring Color Codes and PIN Configurations

Summary of Contents for HubSat42WPV

Page 1: ...Guide Models Include HubSat4WPV Four 4 Channel Outdoor Passive UTP Transceiver Hub with Integral Camera Power HubSat42WPV Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayAv Video Balun Combiners HubSat43WPV Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayDv Video Balun Combiners ...

Page 2: ...ceiver Hubs pg 4 Alternate 24VAC Fixed Camera Hookup pg 5 HubSat Circuit Board pg 6 HubWayAv HubWayAv2 HubWayDv and HubWayDvi Video Balun Combiners pg 7 CAT 5 Structured Cable Wiring Color Codes pg 7 Typical Application Drawings HubSat4WPV Passive UTP Transceiver Hub with Integral Camera Power pg 9 HubSat4WPV Remote Accessory Module with HubWay UTP Transceiver Hubs pg 9 Wall Mount Installation pg ...

Page 3: ...o line up with the top and bottom holes of the enclosure flange Secure enclosure with appropriate fasteners Enclosure Dimensions pg 12 Pole Mount Refer to the detailed pole mount instructions pg 10 Secure enclosure to earth ground 4 Set illuminated master power disconnect circuit breaker to the OFF position Fig 4a pg 8 5 Connect 220VAC 50 60Hz to the black and white flying leads of open frame tran...

Page 4: ...g 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c An individual power output voltage switch is set to the OFF position Fig 2d pg 6 d A PTC is tripped due to a short circuit or overload condition for one or more channels power outputs To reset the PTC 1 Set the voltage output...

Page 5: ... 10 The power LEDs Green of the HubSat4WPV will illuminate when AC power is present Fig 2e pg 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c An individual power output voltage switch is set to the OFF position Fig 2d pg 6 d A PTC is tripped due to a short circuit or overloa...

Page 6: ... out to HubWay HubWayLD or HubWayLDH enables transmission of up to four 4 video signals Pin out configuration pg 7 2h Data CAT 5 or higher structured cable to data port on HubWay HubWayLD or HubWayLDH or head end equipment DVR 2i Channels 1 4 CAT 5 or higher structured cable to cameras Pin out configuration pg 7 PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3 PVD4 DATA DATA 1 4 VIDEO 1 4 28VAC 24VAC 28...

Page 7: ...s RJ45 Jack RJ45 Jack To BNC Connector of Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 3 Fig 3a Fig 3c Fig 3b Fig 3d Fig 3e HubWayAV2 Video from Camera Data to Camera Power ...

Page 8: ...WPV Green Ground Wire Input 220VAC 50 60Hz Fig 4a Illuminated master power disconnect circuit breaker OFF position circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated Fig 4b Fig 4 ...

Page 9: ... Equipment DVR RS485 Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat4WPV 24VAC Fixed Camera Video Power HubWayDv Dvi Video Balun Co...

Page 10: ...hrough the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 9 pg 10 and Fig 11 pg 10 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 10 pg 10 4 Thread the second wormgear quick release strap through the slots on the back ...

Page 11: ...HubSat4WPV 11 Notes ...

Page 12: ...y be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qual...