- 4 -
HubSat4WPiV
7. Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2 or HubWayDv Video Balun/Combiners
to data input terminals of cameras for PTZ control (Figs. 2b-2d, pg. 6). Polarity must be observed.
When using fixed cameras disregard this step.
8. Connect the BNC connector of HubWayAv, HubWayAv2 ot HubWayDv Video Balun/Combiners to the
BNC video outputs of cameras (Figs. 2b-2d, pg. 6).
9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6).
10. The power LEDs (Green) of the HubSat4WPiV will illuminate when AC power is present (Fig. 2e, pg. 4).
Note: If any of the power LEDs are not illuminated the cause may be due to the following:
a. AC mains fail.
b. Illuminated master power disconnect circuit breaker is tripped.
c. An individual power output voltage switch is set to the OFF position (Fig. 2d, pg. 4).
d. A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must
remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 2d, pg. 4).
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 2d, pg. 4).
Alternate 24VAC fixed camera hookup (Fig. 7a, pg. 7).
After completing steps 1-5 of Installation Instructions Remote Accessory Module for use with HubWay, HubWayLD or
HubWayLDH UTP Transceiver Hubs proceed with the following.
1. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5a, pg. 6).
2. Connect one end of the coaxial cable to the BNC connector marked [Video1] on HubSat4WPiV (Fig. 2a, pg. 4).
Connect the opposite end of the coaxial cable to the BNC video output of camera 1 (Fig. 7a, pg. 7).
3. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5a, pg. 6) measure the
output voltage at terminal pair marked [AUX1] on HubSat4WPiV to insure proper operation and avoid possible
damage
(Fig. 2b, pg. 4).
4. Connect the power output terminal pair marked [AUX1] on HubSat4WPiV to the power inputs of camera 1
(Fig. 2c, pg. 4). Repeat steps 1-3 for each additional camera [AUX2-4].
Right Panel
Left Panel
Suggested Locations
for Wire Entries
Bottom Panel
Suggested Locations
for Wire Entries
Fig. 1
HubWayAv, HubWayAv2, and HubWayDv Video Balun/Combiners:
Altronix
Model Number
Input Voltage
from HubWay Unit Output Voltage to Camera
Camera Type
Power
LED
HubWayAv
*24VAC/28VAC
*24VAC/28VAC
*24VAC/28VAC
Green
HubWayAv2
*24VAC/28VAC
*24VAC/28VAC
*24VAC/28VAC
N/A
HubWayDv
*24VAC/28VAC
12VDC
12VDC cameras
Red
*Based on camera load and structured cable length.