Altronix HubSat42WP Installation Manual Download Page 3

 

HubSat4WP 

- 3 - 

10.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6). Power LEDs    

 

(Green) of the HubSat4WP will illuminate when AC power is present (Fig. 2e, pg. 5) and HubWayAv, HubWayDv or   

 

HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 3b, 3d, pg. 5).

11.  Measure the output voltage at each Video Balun/Combiner (Figs. 3b, 3d, pg. 5) before making connections to

 

each camera to ensure proper operation and avoid possible damage.

12.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).

13.  Connect power outputs of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to power   

 

inputs of cameras (Figs. 3a-3d, pg. 6). Polarity must be observed.

 

•  HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 3a, 3b, 3e, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 3c, 3d, pg. 5).

14.  Connect the terminals marked [+ DATA -- ] of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/  

 

Combiners to data input terminals of cameras for PTZ control (Figs. 3a-3e, pg. 5). Polarity must be observed.

 

When using fixed cameras disregard this step.

15.  Connect the BNC connector of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to    

 

the BNC video outputs of cameras (Figs. 3a-3e, pg. 5).

16.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6).

17.  The power LEDs (Green) of the HubSat4WP will illuminate when AC power is present (Fig. 2e, pg. 5).  

 

Note: If any of the power LEDs are not illuminated the cause may be due to the following:

 

a.  AC mains fail.

 

b.  Illuminated master power disconnect circuit breaker is tripped.

 

c.  An individual power output voltage switch is set to the OFF position (Fig. 2d, pg. 5).

 

d.  A PTC is tripped due to a short circuit or overload condition for one or more channels/power outputs.

 

  To reset the PTC:

 

  1.  Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must 

 

   

remain in the OFF position for approximately 2 minutes in order for the PTC to reset (Fig. 2d, pg. 5).

 

  2.  Eliminate the trouble condition (short circuit or overload).

 

  3.  Set the voltage output selector switch for either 24VAC or 28VAC (Fig. 2d, pg. 5).

HubSat4WP for use as a Remote Accessory Module with HubWay/HubWayLD/HubWayLDH UTP Transceiver Hubs.

After completing steps 1-4 of Installation Instructions for HubSat4WP Outdoor Passive UTP Transceiver Hub with 

Integral Camera Power proceed with the following.

1.  For fixed cameras run a single CAT-5 cable between HubSat4WP and HubWay, HubWayLD or HubWayLDH

 

to allow video transmission of up to four (4) cameras. For PTZs run two (2) CAT-5 cables between HubSat4WP

 

and HubWay, HubWayLD or HubWayLDH (Fig. 6, pg. 7).

 

a.  Connect one (1) of the CAT-5 cables to the RJ45 jack marked [Video 1-4] on HubSat4WP. Connect the

 

  opposite end of this CAT-5 cable into the RJ45 jack marked [CH 1-4] of HubWay, HubWayLD or

 

  HubWayLDH unit (Fig. 6, pg. 7).

 

b.  For data (PTZ) connect the second CAT-5 cable to the RJ45 jack marked [Data 1-4] on HubSat4WP. Connect 

 

  the opposite end of this CAT-5 cable into any unused RJ45 jack marked [1-16] of HubWay, HubWayLD or

 

  HubWayLDH unit (Fig. 6, pg. 7).

 

Note: Data inputs of HubWay, HubWayLD or HubWayLDH units must be wired in parallel for proper operation.

 

When using fixed cameras disregard this step.

2.  Plug the RJ45 connector at one end of the CAT-5 or higher structured cable into the RJ45 jack marked [PVD1]  

 

 

on HubSat (Fig. 2i, pg. 4). Plug the RJ45 connector at the opposite end of the CAT-5 or higher structured 

 

cable into the RJ45 jack of the Video Balun/Combiner to be installed at camera 1.

 

•  For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 3a, 3b, 3e, pg. 5).

 

•  For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 3c, 3d, pg. 5).

 

•  For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 3c, 3d, pg. 5).

 

The total cable distance must not exceed 750 ft. for video transmission between the HubSat4WP and each camera.

 

Repeat this step for all other camera channels [PVD2-4].

3.  Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 4a, pg. 6). Power LEDs 

 

(Green) of the HubSat4WP will illuminate when AC power is present (Fig. 2e, pg. 5) and HubWayAv, HubWayDv

 

or HubWayDvi Video Balun/Combiner LEDs will illuminate indicating power is present (Fig. 3b, 3d, pg. 5).

4.  Measure the output voltage at each Video Balun/Combiner (Figs. 3b, 3d, 3e, pg. 5) before making connections to

 

each camera to ensure proper operation and avoid possible damage.

5.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 4a, pg. 6).

6.  Connect power outputs of HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to power   

 

inputs of cameras (Figs. 3a-2e, pg. 5). Polarity must be observed.

  • HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 3a, 3b, pg. 5).

 

•  HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 3c, 3d, pg. 5).

Summary of Contents for HubSat42WP

Page 1: ...oor Passive UTP Transceiver Hub with Integral Camera Power HubSat42WP Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayAv Video Balun Combiners HubSat43WP Four 4 Channel Outdoor Passive UTP Transceiver includes four 4 HubWayDv Video Balun Combiners Rev 081809 More than just power TM Video Data Power ...

Page 2: ... Power Unit should be installed in accordance with The National Electrical Code and all applicable Local Regulations 1 Remove back plate inside the enclosure by removing the four 4 mounting screws Fig 4 pg 6 2 Mark and drill desired knockouts on the enclosure to facilitate wiring Fig 1 pg 4 3 Secure back plate inside the enclosure with the four 4 mounting screws Fig 4b pg 6 4 Unit can be wall or p...

Page 3: ...ions for HubSat4WP Outdoor Passive UTP Transceiver Hub with Integral Camera Power proceed with the following 1 For fixed cameras run a single CAT 5 cable between HubSat4WP and HubWay HubWayLD or HubWayLDH to allow video transmission of up to four 4 cameras For PTZs run two 2 CAT 5 cables between HubSat4WP and HubWay HubWayLD or HubWayLDH Fig 6 pg 7 a Connect one 1 of the CAT 5 cables to the RJ45 j...

Page 4: ...AC or 28VAC Fig 2d pg 5 Alternate 24VAC fixed camera hookup Fig 6a pg 7 After completing steps 1 5 of Installation Instructions Remote Accessory Module for use with HubWay HubWayLD or HubWayLDH UTP Transceiver Hubs proceed with the following 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 4a pg 6 2 Connect one end of the coaxial cable to the BNC connector marked V...

Page 5: ...d end equipment DVR 2i Channels 1 4 CAT 5 or higher structured cable to cameras 2a 2i 2b 2c 2d 2e 2f 2g 2h 2c Fig 3e HubWayAv2 Video from Camera Data to Camera Power to Camera Cat5 back to HubWay or HubSat VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wire Connectors RJ45 Jack RJ45 J...

Page 6: ...AC 24VAC OFF OFF OFF OFF AUX1 AUX2 BK 24 YL 0 Br AUX3 AUX4 ON Fig 4a Illuminated master power disconnect circuit breaker OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated Fig 4 Fig 4b 1 White Orange VIDEO 2 Orange VIDEO 3 White Green DATA 4 Blue AC 1 5 White Blue AC 2 6 Green DATA 7 White Brown AC 2 8 Brown AC 1 CAT 5 Structured Cable Wiring Color Cod...

Page 7: ...H 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat4WP 115VAC Input 60Hz 24VAC Fixed Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 CAT 5 CAT 5 12VDC F...

Page 8: ...int within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel Wall Mount Installation 1 Place unit at the desired loc...

Page 9: ...crew with flat head screwdriver or 5 16 hex socket driver Fig 8a pg 8 and Fig 8b pg 8 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 8c pg 9 4 Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket Fig 8 pg 9 5 Mount enclosure on...

Page 10: ... 10 HubSat4DWP Notes ...

Page 11: ... 11 HubSat4DWP Notes ...

Page 12: ... 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIHubSat4WP K15Q MEMBER MOUNTING PANEL GALVANIZED CARBON STEEL SHEET 13 330mm 4 05 103mm 6 152 4mm 8 203 2mm 4 21 107mm 12 305mm 6 7 170mm 9 84 250mm 0 08 2mm 14 355 6mm Enclosure Dimensions H x W x D approximate 12 x 8 x 6 304 8mm x 203 2mm x 152 4mm ...