Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local
codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for
the application.
eBridge1PCTX and eBridge1PCRM are not intended to be connected to outside plant leads and should be
installed indoors within the protected premises. eBridge1PCTX and eBridge1PCRM are intended for indoor
use only.
1.
eBridge1PCRM installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s
mounting
hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity to ethernet switch/network,
NVR or video server.
Note: When installing more than one (1) eBridge1PCRM, please allow at least 1” (25mm)
distance between the receivers.
b. Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked
[10/100BaseT]
(Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
d. A local AUX input 24VAC or 24VDC can be used to power the eBridge1PCRM. This will eliminate
the need for the eBridge1PCRM to draw power from the midspan/endspan, thus making the midspan/
endspan additional power available to the end PoE powered device.
2.
eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s
mounting
hole
(Fig. 2a, pg. 3). Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 3).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
Note: eBridge1PCRMT is designed to accommodate Megapixel, HD720, HD1080, and VGA (SD) cameras.
It is important to note that some high resolution and high frame rate cameras may demand faster headend
processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment
is insufficient in speed, the image may show pixelation and latency. It is advisable to pre-test system if unsure.
Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Technical Specifications:
Parameter
Description
Connections
BNC for Coax link. RJ45 for ethernet link.
Input power
requirements
Midspan or endspan port connected. AUX input for powering.
Indicators
Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Green: Power.
Environmental
Conditions
Operating Ambient Temperature: UL60950-1
eBridge1PCRM:
-20ºC to 49ºC (-4ºF to 120.2ºF).
eBridge1PCTX:
For 15W:
-40ºC to 75ºC (-40ºF to 167ºF).
For 30W:
-40ºC to 49ºC (-40ºF to 120.2ºF).
Relative humidity:
85%, +/- 5%.
Storage Temperature: -30ºC to 70ºC (-22ºF to 158ºF).
Operating Altitude: -304.8 to 2,000m.
Regulatory
Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1).
CE approved. C-Tick compliant.
Weights (approx.)
Product: 0.4 lbs. (0.181 kg) | Shipping: 1 lbs. (0.45 kg).
Fig. 1
eBridge1PCRM
eBridge1PCTX
Green LED
indicates
Power
Structured
Cable from
midspan/endspan
Structured
Cable from
IP Camera/Device
Blue LED
indicates
Green LED
indicates
Power
Yellow LED
Coax
Cable from
Aux.
24VAC or
24VDC
Input
Coax
Cable from
indicates PoE
eBridge1PCTX
indicates
Coax Connection
eBridge1PCT or
Blue LED
eBridge1PCRM
Coax Connection
- 2 -
eBridge1PCRMT
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]