background image

 

- 2 - 

ALTV244UL Series

Overview:

Altronix ALTV244UL Series CCTV Power Supplies provide 24VAC or 28VAC distributed via four (4) fuse or 
PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Four (4) Output ALTV244UL Reference Chart:

Altronix 
Model Number

Output Voltage

Total 

 Output Current 

(Power)

Number of Outputs

PTC Protected Outputs

(Class 2 power-limited

for Dry locations - 

Class 3 for Wet locations)

(auto-resettable)

Fuse Protected 

Class 1 Outputs

Individual Output Current 

(max per output, not to 

exceed total output current)

Fuse Ratings

Main Fuse Ratings

Primary In-line Fuse 

Ratings

115VAC 60Hz

Input Current

Agency

Listings

ALTV244UL

24VAC

3.5A

4

P

3.5A

3.5A

5A/

250V

3.5A/
250V

0.9A

28VAC

3A

ALTV244ULX

24VAC

3.5A

4

P

3.5A

3.5A

5A/

250V

3.5A/
250V

0.9A

28VAC

3A

ALTV244ULCB

24VAC

3.5A

4

P

2.5A

5A/

250V

3.5A/
250V

0.9A

28VAC

3A

ALTV244175UL

24VAC

7A

4

P

3.5A

3.5A

10A/

250V

1.76A

28VAC

6.25A

ALTV244175ULCB

24VAC

7A

4

P

2.5A

10A/

250V

1.76A

28VAC

6.25A

Specifications:

Installation Instructions:

1.  Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 
 

in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 

 

the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower 

 

two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s 

 

upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 

 

(Enclosure Dimensions, pgs. 10-12). Secure enclosure to earth ground.

2.  Set power switch on power distribution board marked [PD] to OFF position for models ALTV244UL, 
 

ALTV244ULX or ALTV244ULCB (Figs. 1-3, pgs. 4-6)

Agency Listings:

•  UL Listed for Commercial CCTV Equipment 
  (UL 2044). 
  CUL Listed - CSA Standard C22.2 No.1-98, 
  Audio, Video and Similar Equipment. 
•  CE European Conformity.

Input:

•  115VAC, 50/60Hz.

Output:

•  Four (4) fuse or PTC protected outputs. 
•  24VAC or 28VAC output.
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Surge suppression.

Features:

•  Power ON/OFF switch 
  (ALTV244UL, ALTV244ULX, and 
 ALTV244ULCB).

Features 

(cont’d)

:

•  Illuminated power disconnect circuit breaker 
  with manual reset
 

(ALTV244175UL  and  ALTV244175ULCB).    

•  Unit maintains camera synchronization.
•  Ease of installation saves time & eliminates 
  costly labor.
•  Spare fuses included (on fuse protected models).

Enclosure Dimensions 

(H x W x D)

:

•  ALTV244UL, ALTV244ULCB
  8.5” x 7.5” x 3.5” 
  (215.9mm x 190.5mm x 88.9mm).
•  ALTV244175UL, ALTV24175ULCB
  12” x 7.5” x 4.5” 
  (304.8mm x 190.5mm x 114.3mm).
• ALTV244ULX
  13.5” x 13” x 3.25” 
  (342.9mm x 330.2mm x 82.6mm).

Summary of Contents for ALTV244175UL

Page 1: ...3A 85VA Four 4 Fuse Protected Outputs ALTV244ULX 24VAC 3 5A 85VA or 28VAC 3A 85VA Four 4 Fuse Protected Outputs ALTV244175UL 24VAC 7A 175VA or 28VAC 10A 300VA Four 4 Fuse Protected Outputs ALTV244ULCB...

Page 2: ...the screw heads protruding Place the enclosure s upper keyholes over the two upper screws level and secure Mark the position of the lower two holes Remove the enclosure Drill the lower holes and insta...

Page 3: ...Set power switch on power distribution board marked PD to ON position for models ALTV244UL ALTV244ULX or ALTV244ULCB Figs 1 3 pgs 4 6 10 Green LED will illuminate when power is present 11 Upon comple...

Page 4: ...er limited 1P 1N 2P 2N 3P 3N 4P 4N LED 3 5A 250V 3 5A 250V 3 5A 250V N P S MAIN FUSE Class 1 Outputs ON OFF 24VAC or 28VAC Output 1 Follow same procedure using terminals 2P N through 4P N for outputs...

Page 5: ...2P 2N 3P 3N 4P 4N LED N P S MAIN FUSE ON OFF 24VAC or 28VAC Output 1 Follow same procedure using terminals 2P N through 4P N for outputs 2 through 4 24VAC configuration Class 2 Not Wet Class 3 Wet 28...

Page 6: ...ad Input 115VAC 50 60Hz non power limited Green Lead ground Class 1 Outputs 1P 1N 2P 2N 3P 3N 4P 4N LED 3 5A 250V 3 5A 250V 3 5A 250V N P S MAIN FUSE ON OFF Fig 3 ALTV244ULX N P S N P S 24VAC Output 2...

Page 7: ...3 5A 250V N P S MAIN FUSE Class 1 Outputs 24VAC or 28VAC Output 1 Follow same procedure using terminals 2P N through 4P N for outputs 2 through 4 Green Lead ground Black Lead White Lead Input 115VAC 5...

Page 8: ...through 4P N for outputs 2 through 4 1P 1N 2P 2N 3P 3N 4P 4N LED N P S MAIN FUSE ON OFF 24VAC configuration Class 2 Not Wet Class 3 Wet 28VAC configuration Class 1 Green Lead ground Black Lead White L...

Page 9: ...ALTV244UL Series 9 Notes...

Page 10: ...5 133 35mm 6 05 153 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 375mm 0 6 15 24mm 1 25 4mm 1 25 4mm 0 6 15 24mm 0 6 15 24mm 1 125 28 575mm 0 6 15 24mm 3 625 184...

Page 11: ...6mm 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm 5 10 130mm 5 10 130mm 13 0 330mm 5 10 130mm 6 5625 167mm 1 20 31mm 1 20 31mm 1 20 31mm 3 25 83mm 3 25 83mm 3 25 83mm 3 25 83mm 1 0 25m...

Page 12: ...Series C30R MEMBER 1 25 31 75mm 0 5 12 7mm 0 5 12 7mm 1 5 12 7mm 1 25 31 75mm 1 5 12 7mm 3 5 88 9mm 3 5 88 9mm 3 5 88 9mm 1 25 4mm 1 25 4mm 5 75 146 05mm 1 25 4mm 1 13 28 7mm 5 88 149 35mm 0 88 22 35m...

Reviews: