- 8 -  

ALTV2416UL Series

Transformer  

underneath 

power supply  

board 

3.5A 250V 

For continuous protection against risk of fire  

replace fuses with same type and rating. 

common  

outputs 

protected  

outputs 

P

N

XFMR*

N

P

S

X

FM

R

 I

np

ut

1 2 3 4 5 6 7 8  

9 10 11 12 13 14 15 16 

P

N

Illuminated Power Disconnect  

Circuit Breaker with manual reset 

Fig. 5 
ALTV2416300ULM

Transformer  

underneath 

power supply  

board 

Illuminated Power Disconnect  

Circuit Breaker with manual reset 

P

N

N

P

S

X

FM

R

 I

np

ut

common  

outputs 

protected  

outputs 

1 2 3 4 5 6 7 8  

9 10 11 12 13 14 15 16 

N

P

Fig. 6 
ALTV2416300ULCBM

Fig. 5a

Fig. 6a

Summary of Contents for ALTV2416300UL

Page 1: ... 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416300ULM ALTV2416300ULCBM 24VAC 12 5 amp 300VA 24VAC 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416600UL ALTV2416600ULCB 24VAC 25 amp 600VA 24VAC 25 amp 600VA or 28VAC 20 amp 560V...

Page 2: ...Specifications Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 NFPA 72 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Mount unit in desired location Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in ...

Page 3: ...istribution board marked PD to OFF position for models ALTV2416ULX or ALTV2416ULCBX Figs 1 2 pgs 4 5 Set power disconnect circuit breaker to OFF position for all other models Figs 3a 8a pgs 6 10 8 Connect devices to terminals marked 1P 1N through 8P 8N on PD8 board Figs 1 4 pgs 4 7 Figs 7 8 pgs 9 10 or terminals marked 1P 1N through 16P 16N on PD16W PD16WCB board Figs 5 6 pg 8 carefully observing ...

Page 4: ...C or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 Class 1 Outputs Fig 1 ALTV2416ULX The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation po...

Page 5: ...0 Hz White Lead Black Lead XFMR XFMR non power limited non power limited Black Lead Ground Primary In line Fuse 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet 28VAC configuration Class 1 24VAC config...

Page 6: ...M M O N P O W E R O U T P U T S P F U S E D P O W E R O U T P U T S 1 2 3 4 5 6 7 8 D1 INPUT N P S R1 LED MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 throu...

Page 7: ... 115VAC input 60 Hz XFMR Ground Connected to Door non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC configuration Class 2 Not Wet Class 3 Wet 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24V...

Page 8: ...s P N XFMR N P S XFMR Input 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P N Illuminated Power Disconnect Circuit Breaker with manual reset Fig 5 ALTV2416300ULM Transformer underneath power supply board Illuminated Power Disconnect Circuit Breaker with manual reset P N N P S XFMR Input common outputs protected outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Fig 6 ALTV2416300ULCBM Fig 5a Fig 6a ...

Page 9: ...MR Black Lead 115VAC input 60 Hz Ground Connected to Door non power limited non power limited non power limited MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2...

Page 10: ...Hz Ground Connected to Door non power limited non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet XFMR 24...

Page 11: ...1 1 00 1 75 1 00 1 25 1 25 8 13 1 00 1 00 1 25 8 13 7 25 7 25 1 00 3 85 0 60 1 00 3 85 1 00 0 60 7 25 3 63 1 25 0 90 0 60 3 85 0 60 0 90 8 13 Enclosure Dimensions for ALTV2416300ULM ALTV2416300ULCBM 8 5 H x 7 5 W x 3 75 D ...

Page 12: ...th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A II1ALTV2416ULSeries G16L Enclosure Dimensions for ALTV2416ULX ALTV2416ULCBX ALTV2416300UL ALTV2416300ULCB ALTV2416600UL ALTV2416600ULCB 13 5 H x 13 W x 3 5 D ...

Reviews: