Altronix AL400ULXJ Installation Manual Download Page 6

 

- 6 - 

AL400ULXJ Installation Guide

Appendix A - UL Listed Compatible Devices

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

A.1 Four (4) Wire Smoke Detectors

Table A-1 below lists four (4) wire smoke detectors compatible with AL400ULXJ output.

System Sensor

Smoke Detector/Base

Detector Type

Max Stand-by 

Current (mA)

Alarm Current 

(mA)

B112LP

Base

0.12

36

B114LP

Base

*

*

B404B

Base

*

*

DH100ACDC

Photoelectric

0.15

0.70

DH100ACDCLP

Photoelectric

0.15

0.70

DH100ACDCLPW

Photoelectric

0.15

0.70

DH400ACDCI

Ionization Duct

25

95

DH400ACDCP

Photoelectric Duct

25

95

1112/24/D

Ionization

0.05

50

1424

Ionization

0.10

41

1451 (w/B402B Base)

Ionization

0.10

39

2112/24ATR

Photoelectric

0.50

60/70

2112/24AITR

Photoelectric

0.50

60/70

2112/24/D

Photoelectric

0.05

50

2112/24T/D

Photoelectric w/135

o

 Thermal

0.05

50

2112/24TSRB

Photoelectric w/135

o

 Thermal Supervisory Relay

15

45

2312/24TB

Photoelectric

0.12

50

2412 (12 volt)

Photoelectric

0.12

77

2424

Photoelectric

0.10

41

2451

Photoelectric

0.10

39

2451TH (with/B402B Base)

Photoelectric

0.10

39

2W-MOD

Loop Test/Maintenance Mod.

30

50

4W-B (12/24 volt)

Photoelectric I

3

0.05

23

4WT-B (12/24 volt)

Photoelectric I

3

 w/Therm

0.05

23

4WTA-B (12/24 volt)

I

Photo w/Therm/Sounder

0.05

35

4WTR-B (12/24 volt)

I

Photo w/Therm/Relay

0.05

35

4WITAR-B (12/24 volt)

I

Photo w/Isolated Therm/Sounder/Relay

0.05

50

2W-MOD2

I

Loop Test/Maintenance Mod.

0.05

*

RRS-MOD

I

Reversing Relay/Sync Module

0.05

*

6424

Projected Beam

10

28.4

Beam 1224(S)

Projected Beam

17

38.5

* Contact manufacturer for current draws.

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

A.2 Relays

Table A-2 below lists relays compatible with AL400ULXJ output.

Manufacturer

Model

Current (mA)

Manufacturer

Model

Current (mA)

System Sensor

PR-1

PR-2

PR-3

 EOLR-1

R-10T

R-14T

15

30

30

30

23

23

System Sensor

R-20T

R-24T

R-10E

R-14E

R-20E

R-24E

40

40

23

23

40

40

Summary of Contents for AL400ULXJ

Page 1: ...dd a G suffix to the part number AL400ULXJ Power Supply Charger Installation Guide Rev 030619 More than just power TM Installing Company ________________ Service Rep Name _____________________________...

Page 2: ...ulated output s Short circuit and thermal overload protection LED Indicators AC input DC output and Battery LED indicators Battery Backup Built in charger for sealed lead acid or gel type batteries Au...

Page 3: ...ee list refer to Appendix A pg 6 4 Measure output voltage before connecting devices This helps avoiding potential damage When servicing the unit AC mains should be removed 5 Connect devices to the ter...

Page 4: ...elay normally ener gized when AC power is present Contact rating 1A 28VDC AC Fail condition will report approximately within one 1 minute after loss of AC To delay report for 6 hours cut jumper J1 on...

Page 5: ...electric shock and fire hazard replace fuse with the same type and rating Do not expose to rain or moisture CAUTION Optional rechargeable stand by batteries must match the power supply output voltage...

Page 6: ...ic w 135o Thermal Supervisory Relay 15 45 2312 24TB Photoelectric 0 12 50 2412 12 volt Photoelectric 0 12 77 2424 Photoelectric 0 10 41 2451 Photoelectric 0 10 39 2451TH with B402B Base Photoelectric...

Page 7: ...AL400ULXJ Installation Guide 7 Notes...

Page 8: ...38 1mm 1 5 38 1mm 1 5 38 1mm 2 5 63 5mm 2 5 63 5mm 14 5 368 3mm 14 5 368 3mm 4 5 114 3mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm Enclosure Dimensions H x W x D approximate 18 x 14 5 x 4 625 457 2...

Reviews: