background image

 

- 8 - 

AL300ULX Series

Enclosure Dimensions 

(BC400)

:

AL300ULXX, AL300ULXXR, AL300ULXPD4, AL300ULXPD4CB,
AL300ULXPD8, AL300ULXPD8CB, AL300ULXPD16, AL300ULXPD16CB

15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm)

1.5”

(38.1mm)

1.5”

(38.1mm)

4.615” (117.2mm)

4.615” (117.2mm)

1.5”

(38.1mm)

1.5”

(38.1mm)

4.615” (117.2mm)

4.615” (117.2mm)

1.75”

(44.5mm)

1.75”

(44.5mm)

1.375”

(34.9mm)

1.125”

(28.6mm)

1.5”

(38.1mm)

1.5”

(38.1mm)

5.0”
 (127.0mm)

5.0”
 (127.0mm)

4.5” (114.3mm)

4.5” (114.3mm)

1.25”

(31.8mm)

1.25”

(31.8mm)

0.79”

 (20.1mm)

0.91”

 (23.1mm)

0.91”

 (23.1mm)

15.5”

 (393.7mm)

1.1” (27.9mm)

1.1” (27.9mm)

1.1” (27.9mm)

12.23” (310.6mm)

2.0”

(50.8mm)

2.0”

(50.8mm)

1.25” (31.8mm)

1.25” (31.8mm)

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty | Made in U.S.A.

IIAL300ULX Series 

G01U

MEMBER

Summary of Contents for AL300ULPD4

Page 1: ...X Series Power Supply Charger Models Include For a red enclosure add an R suffix to the part e g AL300ULPD8R Installation Guide AL300ULX Single Output AL300ULPD4 Four 4 Fuse Protected Outputs AL300ULP...

Page 2: ...s UL 1069 UL Listed Hospital Signaling and Nurse Call Equipment UL 1481 UL Listed for Power Supplies for Fire Protective Signaling Systems Signal Equipment Evaluated to CSA Standard C22 2 No 205 M1983...

Page 3: ...tch Position 24VDC SW1 OFF 12VDC SW1 ON Battery AC Supervision Circuit power limited J1 AC Delay Green Lead 115VAC power mains non power limited Class 1 DC Output to devices power limited CAUTION When...

Page 4: ...ualified service personnel For Fire Alarm applications the outputs are Special Applications only see list refer to Appendix A pg 6 For other devices contact Underwriters Laboratories to ensure compati...

Page 5: ...by battery connections Maximum charge current 0 7A Power Distribution Module Terminal Legend Function Description PD4UL PD4ULCB PD8UL PD8ULCB 1P to 4P 1P to 8P Positive DC power outputs 1N to 4N 1N to...

Page 6: ...35o Thermal Supervisory Relay 15 45 2312 24TB Photoelectric 0 12 50 2412 12 volt Photoelectric 0 12 77 2424 Photoelectric 0 10 41 2451 Photoelectric 0 10 39 2451TH with B402B Base Photoelectric 0 10 3...

Page 7: ...6mm 1 40 35 6mm 1 40 35 6mm 1 40 35 6mm 4 85 123 2mm 4 85 123 2mm 3 25 82 6mm 0 75 19 1mm 0 75 19 1mm 11 0 279 4mm 12 5 317 5mm 1 20 30 5mm 1 20 30 5mm 0 9375 23 8mm 0 9375 23 8mm 5 10 129 5mm 1 40 35...

Page 8: ...m 1 375 34 9mm 1 125 28 6mm 1 5 38 1mm 1 5 38 1mm 5 0 127 0mm 5 0 127 0mm 4 5 114 3mm 4 5 114 3mm 1 25 31 8mm 1 25 31 8mm 0 79 20 1mm 0 91 23 1mm 0 91 23 1mm 15 5 393 7mm 1 1 27 9mm 1 1 27 9mm 1 1 27...