AL175220 Series

Overview:

Altronix AL175220 and AL175X220 are power-limited power supply/chargers that converts 220VAC (working 
range 198VAC - 256VAC), 50/60Hz input into two individually PTC protected auto-resettable 12VDC or 24VDC 
outputs (see specifications). They are intended for use in Access Control applications and applications requir-
ing an interface with the Fire Alarm Control Panels. They must be installed in accordance with National and 
Local Electrical Codes and Regulations.

Specifications:

Power Supply Output Specifications:

Output 
VDC

Switch Position

Max. Stand-by 

Load DC

Max. Alarm 

Load DC

Battery 

(optional)

12VDC

SW1 OFF

1.75A

1.75A

12VDC

24VDC

SW1 ON

1.75A

1.75A

Two (2) 12VDC

Stand-by Specifications:

Output

4 hr. of Stand-by and 5 Minutes of Alarm

12VDC / 7 AH Battery

Stand-by = 1.25A
Alarm = 1.25A

24VDC / 7 AH Battery

Installation Instructions:

The units should be installed in accordance with article 760 of The National Electrical Code or NFPA 72 as 
well as all applicable Local Codes.
See Terminal Identification Chart on Pg. 3 for a description of each terminal function.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 
  in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 
  the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower 
  two holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper 
  keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 
  (Enclosure Dimensions, pgs. 7-8).
2. Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to the 
  terminal marked     , Line connects to the terminal marked [L], and Neutral connects to the terminal marked 
  [N] of the Inlet Appliance Connector. (Fig. 1, pg. 4)
  Use 18 AWG or larger for all power connections. 
  Use 18 AWG or larger for all power connections (Battery, AC input, DC outputs). 
  Use 22 AWG to 18 AWG for power-limited circuits (trigger inputs, dry outputs).
  Keep power-limited wiring separate from non power-limited wiring (220VAC, 50/60Hz Input, Battery 
  Wires). Minimum 0.25” spacing must be provided.
  CAUTION: Do not touch exposed metal parts. 
  Shut branch circuit power before installing or servicing equipment. 
  There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.

Input:

•   Input 220VAC, 50/60 Hz, 0.3A.

Output:

•  12VDC or 24VDC selectable output.
•  Power-limited outputs.
•  1.75A continuous supply current @ 
  12VDC or 24VDC.
•  Aux relay output (form “C” contacts).
•  Filtered and electronically regulated output.
•  Short circuit and thermal overload protection.

Battery Backup:

•  Maximum charge current: 400mA.
•  Automatic switch over to stand-by battery 
  when AC fails.

Supervision:

•  AC fail supervision (form “C” contacts). 
•  Dry trigger output (form “C” contacts). 

Fire Alarm Interface:

•  Dry trigger input.

Visual Indicators:

•  AC input and DC output LED indicators.

Added Features:

•  Includes power supply, transformer, and enclosure.

Enclosure Dimensions:

AL175220:
  8.5” x 7.5” x 3.5” 
  (215.9mm x 190.5mm x 88.9mm).
AL175X220:
  13.5” x 13” x 3.25” 
  (342.9mm x 330.2mm x 82.6mm).

Black Lead

White Lead

Stand-by

Battery

(optional)

Constant output

(Not affected

by trigger)

Switched

DC output

(trigger control)

NC

DC

AC

C

TRG1 TRG2

AC

AC

+ BAT --

COM --

AUX --

LOCK +

AUX + FACP

SW1 ON - 24V

OFF - 12V

SW1

VR1

NO

NC

C

NO

AC F
AIL

ON

 Input 220VAC

50/60Hz, 0.3A

XFMR

Summary of Contents for AL175220 Series

Page 1: ...Power Supply Chargers Models Include AL175220 Enclosure Dimensions 8 5 x 7 5 x 3 5 215 9mm x 190 5mm x 88 9mm Accommodates one 1 12VDC 4AH battery AL175X220 Enclosure Dimensions 13 5 x 13 x 3 25 342 9...

Page 2: ...yholes over the two upper screws Install the two lower screws and make sure to tighten all screws Enclosure Dimensions pgs 7 8 2 Connect unswitched AC circuit 220VAC 50 60Hz as follows Green branch wi...

Page 3: ...hat there is no break in the battery connection wires Note Maximum charging current under discharges is 400mA Note Expected battery life is 5 years however it is recommended changing batteries in 4 ye...

Page 4: ...ad Stand by Battery optional Constant output Not affected by trigger Switched DC output trigger control NC DC AC C TRG1 TRG2 AC AC BAT COM AUX LOCK AUX FACP STRIKE SW1 ON 24V OFF 12V SW1 VR1 NO NC C N...

Page 5: ...OCK STRIKE TRG2 TRG1 AUX AUX COM Fig 2 Typical single mag lock or door strike installation with fire alarm tie in using trigger controlled output FACP MAG LOCK MAG LOCK ACCESS CONTROL DEVICE LOCK STRI...

Page 6: ...using aux output installation FACP MAG LOCK ACCESS CONTROL DEVICE AUX FACP AUX NO RESET SWITCH FACP MAG LOCK ACCESS CONTROL DEVICE LOCK STRIKE TRG2 TRG1 C NO NC COM Fig 5 Latching fire alarm tie in w...

Page 7: ...53 67mm 6 05 153 67mm 3 5 88 9mm 3 5 88 9mm 7 25 184 15mm 2 50 8mm 2 50 8mm 8 125 206 375mm 0 6 15 24mm 1 25 4mm 1 25 4mm 0 6 15 24mm 0 6 15 24mm 1 125 28 575mm 0 6 15 24mm 3 625 184 15mm Enclosure Di...

Page 8: ...C21R MEMBER 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm 5 10 130mm 5 10 130mm 13 0 330mm 5 10 130mm 6 5625 167mm 1 20 31mm 1 20 31mm 1 20 31mm 3 25 83mm 3 25 83mm 3 25 83mm 3 25 83mm...

Reviews: