AL100UL Installation Guide

Altronix is not responsible for any typographical errors.

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty 

IIAL100UL F29U

MEMBER

7.25” (184.2mm)

3.625” (92mm)

1.25”

(31.8mm)

3.5” (88.9mm)

6.05” (153.7mm)

1.125”

(28.6mm)

1.125”

(28.6mm)

0.6” (15.2mm)

0.6” (15.2mm)

0.6” (15.2mm)

0.6” (15.2mm)

2” (50.8mm)

2” (50.8mm)

8.125” (206.4mm)

1”

(25.4mm)

1”

(25.4mm)

1”

(25.4mm)

1.25”

(31.75mm)

1.25”

(31.75mm)

1”

(25.4mm)

1”

(25.4mm)

5.25” (133.35mm)

6.05” (153.7mm)

3.5” (88.9mm)

Enclosure Dimensions 

(H x W x D)

8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 

to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of 

sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-

tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION:

 To reduce the risk of electric shock do not open 

enclosure. There are no user serviceable parts inside. Refer servicing 

to qualified service personnel.

Summary of Contents for AL100UL

Page 1: ...ply Charger Installation Guide Rev 050101 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ ...

Page 2: ...or use only 1 Mount the unit in the desired location Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in the wall with the screw heads protruding Place the enclosure s upper keyholes over the two upper screws level and secure Mark the position of the lower two holes Remove the enclosure Drill the lower holes and instal...

Page 3: ...r it is recommended changing batteries in 4 years or less if needed Terminal Identification Terminal Legend Function Description AC AC Low voltage AC input 16 5VAC 20VA UL Listed Class 2 plug in transformer DC 12VDC 750mA continuous power limited output BAT Stand by battery connections Maximum charge rate 500mA AC FAIL NC C NO Indicates loss of AC e g connect audible device or alarm panel Relay is...

Page 4: ... 153 7mm 3 5 88 9mm Enclosure Dimensions H x W x D 8 5 x 7 5 x 3 5 215 9mm x 190 5mm x 88 9mm The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle i...

Reviews: