6062 Typical Applications
Fig. 1 - Timed Door Annunciator:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 5 - Timed Door Strike:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 2 - Guard Tour Supervisory Timer:
For this application Switch #1 and Switch #4 should be
in the OFF position.
Fig. 6 - Timed Shunt for a Door:
Use to bypass
alarm contacts.
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
CHIME
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Normally open door contacts
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
DIALER OR
TRANSMITTER
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Normally open switch contacts
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Pos (+) and
Neg (-) termi-
nals constant
12 or 24VDC
+
--
Normally open door contacts
Door Strike
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Normally open switch contacts
Door Contacts
Protective Circuit
+
--
+
--
Fig. 3 - Swinger Eliminator:
For this application Switch #1 should be in the OFF
position and Switch #4 should be in the ON position.
Fig. 7 - Bell Cut Off Timer:
For this application Switch #1 should be in the ON position
and Switch #4 is not used in this application.
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Control Panel
12 or 24VDC
BELL
OUTPUT
BELL OR
SIREN
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Pos (+) and Neg (-)
terminals constant 12
or 24VDC
+
--
Protective
Circuit
Closed Circuit
Zone on Control Panel
+
--
Fig. 8 - Closed Circuit Trigger Option:
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Power
Supply
+
--
closed
circuit contact
Fig. 4 - Delay Timer:
Use for Door Ajar Alarm,
Delayed Activation of Digital Dialer, Defrost Cycle
Timer, etc...
For this application Switch #1 should be in the ON
position and Switch #4 is not used in this application.
CUT
JI
FOR
REPEA
T
J1
1
2
3
4
ON
TRIG
CONTROL
4
12V
/
24V
3
SEC.
/
MIN.
2
RELA
Y
CONTROL
1
TRG
---
+
NO
C
NC
1
ON
OFF
15
CUT
J3
FOR
RESET
ON
POWER-UP
J3
CUT
J2
FOR
DELA
Y
PULSE
J2
45
60
Pos (+) and Neg (-)
terminals constant
12 or 24VDC
+
--
Use appropriate contacts to reporting devices
Normally open triggering device
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
web site: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
II6062 - Rev. 120104
L01D
MEMBER
Pull up resistor
For this application a resistor [for 12VDC - 2K
(2,000 ohm) or for 24VDC - 4.7K (4,700 ohm)] must be
installed as shown. (resistor not supplied)