8
BUILDING EDGE PROTECTION SYSTEM Instruction for use
Ø33,7 x 2,6
150
628
≤470
≤470
≥1100
≥1100
≤470
≤470
200
2600
3000
• The main railings are installed by positioning the pipes
Ø33,7 x 2,6
on the upper mounting rods and locking them
by hitting the end rod with the 600 g hammer from above
• The intermediate railings are installed by positioning the
pipes
Ø33,7 x 2,6
on the bottom mounting rods and locking
them by hitting the end rod with the 600 g hammer from
above. The railing pipes must always be located on the in-
side of the building.
• The railing pipes should protrude beyond the supporting
points (posts) by at least
200 mm
. Typical railing pipes are
marked red over
200 mm
at both ends. This is the marking
of the zone that protrudes beyond the posts (fig. 7 and 8).
fig. 6 – System segment positioned longitudinally
toeboard fastening
nail
toeboard fastening
nail
toeboard
fastening nail
fig. 7 – Installation of the toeboard and railing in the corners
fig. 8 – General diagram
3 QUICK ASSEMBLY GUIDE