background image

 

 

1) 

By default, the module uses the option of forwarding all incoming 

SMS that are not commands to the last phone number registered in the 
module or entered into cells NUM1/2/3.
To deactivate this option use commands SMSF0.

 

 

2) 

Automatic SMS notifications (1-ON, 0-OFF):

SMSW1 - transmitting SMS status when the heater's status changes

;

SMSE1 - notifications about heater's operation errors

;

SMSV:XX - alarm SMS about voltage dropping below value XX

;

SMST:XX - information SMS about increasing of the car interior sensor's 
(supplied with module)  temperature value above XX.
 

3) BTIMER1:N allows receiving SMS with account balance every N days.

To request the account balance of the SIM card (by number from the BAL 
setting) use SMS command 

«

USSD

». 

If you need to request data for another 

phone number, add it in the command: 

«

USSD:

*

XXX#

»

.

Note

:

 MCC, MNC, LAC and CID data allow to determine the location of the 

vehicle on the map (using Google, Yandex services, etc.).
LAC and CID fields values are displayed in hexadecimal notation

.

Note

diagnostics is only possible for digital heaters

.

Settings

You can enter several settings simultaneously, dividing them by commas. 
If the password is set (PASS:XXXX), then before entering any instruction, 
you should include its value with no spaces (XXXXSETTINGS1).

 

1) 

On the first launch the module automatically detects the type of the 

digital heater. For the forced change of the connected heater's type use 
text message instruction HEATER-XX, where XX: 
A

0 – 

Automatic determination of the heater's type (digital/analog);

 

А1 - 

Analog heater

;  

 

 

W1 –

 

Thermo Top C/Z/V/EVO

/

VEVO; 

W2 –

 

Thermo Top V

/

VEVO; 

 

W3 – WTT Emulation;   

W4 – Timer 1533 Emulation;   

W5 – Telestart (ver.1) Emulation; 

W6 – Telestart (ver.2) Emulation;  

W

7 – 

Ventilation (summer mode).

 

2) 

To change the default operation time of the heater use text message 

command TIME1:XX, where XX is operation time from 10 to 120 minutes.

 

3) 

If output OUT controls ventilation of the car's interior set up the 

delay time for switching on output OUT using setting TIME2:XX and/or set 
up switching of output OUT based on the 

coolant temperature

 using setting 

LTEMP1:XX, where value ХХ can be from 0 to 99°С (0 - the setting is OFF).

 

4) 

Settings LTEMP2:XX and LTEMP3:XX allow switching the heater off 

based on the cool

ant

 temperature or car interior's temperature sensor's 

data (

supplied with module

) before the operation time TIME1:XX.

   

Additional commands

Command

Send USSD-request *XXX# using the module's SIM card

USSD:*XXX#

Send text message ХХХ from SIM card's number to NNN SMS:NNN:XXX
Request GSM stations data (MCC,MNC,LAC,CID)

GSMINFO

Heater's Diagnostics

Command

Read heater's errors

READ

Erase heater's errors

ERASE

General Settings Commands

Command

Request a text message (SMS) with general settings

SETTINGS1

Request a text message (SMS) with Internet settings

SETTINGS2

Restore to factory default settings

SETDEFAULT

Technical Settings

Command

Type of connected heater (see the description above)

HEATER-XX

Shut off heater when there are errors on digital bus

RSTOP1 /0

Binding to other control modules

BIND1 /0

Default operating time of heater, 10–120 min

TIME1:30

Delay before switching on of OUT, 1–20 min

TIME2:0

Delay before switching off of OUT, 1–9 min

TIME3:0

Permitted n

umber of errors

 in the heater

, 0-99

ERRCTRL:10

Switch off OUT by coolant temp, 0-OFF (0-99°С)

LTEMP1:0

Switch off heater by coolant temp, 0-OFF (0-99°С)

LTEMP2:0

Switch off heater by temp sensor data, 0-OFF (0-99°С) LTEMP3:

0

Type of button: latching / non-latching

FIXKEY1 /0

Pulse mode for OUT, 0-OFF (0-999 sec)

PULSEOUT:0

Switching on of OUT when the digital bus is activated

SEPARLINE1 /0

Manual control of OUT (on/off)

SEPAROUT1 /0

Restoring of the state for OUT after power supply

KEEPOUT1 /0

User Settings

Command

Forwarding of incoming SMS (to switch off use SMSF0)

SMSF1 /0

SMS status when the heater's status changes

SMSW1 /0

SMS about control bus errors

SMSE1 /0

SMS about car system voltage drop

SMSV:11.0

SMS about car interior sensor's temperature

SMST:0

CALL1 - response incoming call, CALL0 - dropping call

CALL1 /0

Setting the password before entering SMS-commands

PASS:XXXX

Save the phone number into cell X, where X - 1, 2, 3

NUMX:+7YYYYY

Save USSD number fore account balance requests

BAL:*XXX#

Timer for sending SMS with balance, 0-99 days (0-OFF)

BTIMER1:10

Timer for sending balance into application, 1-9 hours

BTIMER2:5

Transliteration of cyrillic characters

TRANSLIT1 /0

Reviews: