Alto MISTRAL 6000 User Manual Download Page 2

1

SAFETY RELATED SYMBOLS

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Protective Grounding

The symbol is used to indicate that some hazard-
ous live terminals are involved within this apparatus,
even under the normal operating conditions.

The symbol is used in the service documentation
to indicate that a specific component shall be only
replaced by the component specified in that docu-
mentation for safety reasons.

Protective grounding terminal.

Alternating current /voltage.

Hazardous live terminal.

ON:

Denotes the apparatus is turned on.

OFF:

Denotes the apparatus is turned off, because it uses

the single pole switch, be sure to unplug the AC power to
prevent any electric shock before you proceed with your
service.

WARNING:

Describes precautions that should be

observed to prevent the danger of injury or death to
the user.

CAUTION:

Describes precautions that should be

observed to prevent danger of the apparatus.

WARNING

Power Supply

Ensures the source voltage matches the voltage of the
power supply before turning ON the apparatus.
Unplug this apparatus during lightning storms or when
unused for long periods of time.

External Connection

Do not Remove any Cover

There are maybe some areas with high voltages inside,
to reduce the risk of electric shock, do not remove any
cover if the power supply is connected.
The cover should be removed by qualified personnel
only.
No user serviceable parts inside.

Fuse

dis-connect the power source.

Operating Conditions

This apparatus shall not be exposed to dripping or spl-
ashing and that no objects filled with liquids, such as
vases, shall be placed on this apparatus.
To reduce the risk of fire or electric shock, do not expose
this apparatus to rain or moisture.
Do not use this apparatus near water.
Install in accordance with the manufacturer's instructions.
Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including amp-
lifiers) that produce heat.
Do not block any ventilation openings.
No naked flame sources, such as lighted candles, should
be placed on the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

Read these instructions.

Heed all warnings.

Follow all instructions.

Keep these instructions.

Only use attachments/accessories specified by the manu-

facturer.

Power Cord and Plug

Do not defeat the safety purpose of the polarized or
grounding type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety.
If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched
particularly at the plug, convenience receptacles, and
the point where they exit from the apparatus.

Cleaning

When the apparatus needs a cleaning, you can blow off
dust from the apparatus with a blower or clean with a rag
etc. Don't use solvents such as benzol, alcohol, or other
fluids with very strong volatility and flammability for cleaning
the apparatus body.
Clean only with a dry cloth.

Servicing

Refer all servicing to qualified personnel. To reduce the
risk of electric shock, do not perform any servicing other
than that contained in the operating instructions unless
you are qualified to do so.
Servicing is required when the apparatus has been dam-
aged in any way, such as the power supply cord or plug
is damaged, liquid has been spilled or objects have fallen

rain or moisture, does not operate normally, or has been
dropped.

into the apparatus, the apparatus has been exposed to

Make sure to connect the protective grounding to prevent
any electric shock before turning ON the apparatus.

To prevent a fire, make sure to use fuses with specified
standard (current, voltage, type). Do not use a different
fuse or short circuit the fuse holder.
Before replacing the fuse, turn OFF the apparatus and

The external wiring connected to the output hazardous
live terminals requires installation by an instructed person,
or the use of ready-made leads or cords.

Never cut off the internal or external protective grounding
wire or disconnect the wiring of protective grounding terminal.

Summary of Contents for MISTRAL 6000

Page 1: ...STEREO POWER AMPLIFIER LTO R www altoproaudio com Version 1 0 April 2005 English User s Manual MISTRAL6000 ...

Page 2: ... flame sources such as lighted candles should be placed on the apparatus IMPORTANT SAFETY INSTRUCTIONS Read these instructions Heed all warnings Follow all instructions Keep these instructions Only use attachments accessories specified by the manu facturer Power Cord and Plug Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider tha...

Page 3: ...mments ur job we d like to share with you our work and our dreams paying attention to your suggestions Following this idea we create our products and we will create the new ones From our side we guarantee you and we will guarantee you also in future the best quality and the best fruits of our continuous researches and the best prices Our LTO MISTRAL6000 Stereo Power Amplifier is the result of many...

Page 4: ...TABLE OF CONTENTS 1 INTRODUCTION 4 2 FEATURES 4 3 CONTROL ELEMENTS 5 3 1 The Front Panel 3 2 The Rear Panel 4 APPLICATION 8 4 1 Stereo Mode 5 TECHNICAL SPECIFICATIONS 11 6 WARRANTY 12 3 4 2 Bridge Mode ...

Page 5: ...g conditions An automatic speed fan matches cooling capacity with heat requirements The amplifier frame contains all solid state circuitry using complementary silicon output devices The amplifier is supplied with a single moulded AC cord having an appropriate AC plug for the intended operating voltage The amplifier employs forced air cooling with a variable speed fan for minimum acoustic noise Air...

Page 6: ...it is in heat protection no signal output at the time and over heat inside the unit the temperature the surface temperature of power transistor is 110 must be lowered through better ventilation and decrease the signal level etc After the temperature dropped the protection stop and meanwhile the Led turning off with the unit recover normal work Power Led This Led lights up when the unit is powered ...

Page 7: ...ower cord Manual Reset Pushing Button This switch works as fuse for protecting the unit from damage When the unit is overloaded or the temperature inside the unit is too high this pushing button will spring up and break the power supply The power supply will be restored with pushing this switch down again Output Connector These connectors have two kinds Binding post and Neutrik connector You can c...

Page 8: ...MODE BRIDGE STEREO CH1 OUTPUT1 OUTPUT1 OUTPUT2 OUTPUT2 POWER OUTPUTS POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO BRIDGE MONO CH2 2 2 POS NEG BRIDGE BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 B...

Page 9: ...2 2 2 POS NEG BRIDGE BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PAR...

Page 10: ...ND INPUT Input Connector Balanced MODE Release this button Channel 2 Channel 1 1 2 3 GND INPUT Input Connector Balanced MODE Release this button Channel 2 Channel 1 Channel 1 Channel 1 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT MODE BRIDGE STEREO CH1 OUTPUT1 OUTPUT2 POWER OUTPUTS POWER OUTPUTS C...

Page 11: ...UTPUT2 POWER OUTPUTS POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO BRIDGE MONO CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL O...

Page 12: ... 10K ohms unbalanced 20K ohms balanced 56 36dB FRONT AC SWITCH CH1 CH2 GAIN KNOBS Continuously variable speed fan rear to front air flow On off muting DC fault load grounding relay Internal fault fuses 200 240 100 120 Vac 50 60Hz 19 48 3 cm rack mounting 5 2 13 3 cm tall 3 rack spaces 17 8 45 3 cm deep rack mounting to rear support ears 26 47Kg 1070W 1500W 3000W PRELIMINART Indicators 1 per channe...

Page 13: ...TO of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for LTO parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions Normal...

Page 14: ... com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 c All rights reserved to ALTO All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manual without written permission is forbidden Copyright 2005 SEIKAKU GROUP SEIKAKU TECHNICAL GROUP LIMITED ...