Fault

Cause

Correction

Machine will not start

A fuse has blown

Change the fuse

Power/plug not connected

Connect power/plug

Thermal switch in motor

Let the motor cool. Start the machine and

activated

check that the working pressure is
not too high and that the mains voltage
corresponds to the specifications.

KSA-2 Thermal switch in water tank Let the water cool and check that the inlet

water temp does not exceed 160°F.

Machine stops shortly

Wrong supply voltage

Check that the supply voltage corresponds

after the start

to the specifications on the model tag
(see section 1.1).

Air in the system

Vent the system (see section 3.4).

Fuses blow

Supply is inadequate

Correct the installation so it corresponds to

for the ampere

the ampere consumption of the machine

consumption of the machine

at a minimum. Change fuse.

Working pressure

KSA-1 Nozzle partly clogged

Clear nozzle (see section 6.4)

too high

Working pressure too low

High pressure cock by outlet Close all high pressure cocks not in use.
point not completely closed

KSA-1 Water regulation valve not

Completely open the water regulation valve.

set at max pressure

Turn in the direction of the indicator.

KSA-2 Wrong MULTIPRESSURE

Check whether the total water volume of the

spray lance

spray lances in use exceeds the capacity of
the system. If necessary, change to other
spray lances.

Pressure fluctuating

High pressure hoses too

Detach high pressure extension hoses and

long

(machine vibrates) retry. Extension hose
max. 160 ft.  Avoid long extension hoses
with many couplings.

Air in the system

Vent the system (see section 3.4)

Water inlet screen clogged

Clean the screen (see section 6.3)

No working pressure

Nozzle clogged

Clear the nozzle (see sec. 6.4)

No inlet water

Check that the shut-off cock of the water
supply is open. Check that the water supply
is adequate (see section 1.2).

High pressure cock of

Close all high pressure cocks not in use.

outlet point is open

Water volume too

KSA-1 Water regulation valve not

Open water regulation valve completely.

low

set properly

Turn completely open in the direction of the
indicator.

KSA-2 Nozzle partly blocked

Clear the nozzle (see section 6.4).

Should other malfunctions occur than those mentioned above, please contact your authorized ALTO
servicing distributor.

Customer services (US only):

ALTO U.S. Inc.

Phone: 877-322-2586 (Tech Support)

1500 N. Belcher Rd
Clearwater, FL 33765

Summary of Contents for 52C3KSA -1

Page 1: ...Operator s manual USA IMPORTANT For your own safety and that of others please make certain that everyone who uses the 52C3KSA 1 2 high pressure washer reads and understands these instructions thorough...

Page 2: ...2 C3KSA 1 C3KSA 2...

Page 3: ...ent installation 14 5 0 Applications and working methods 15 5 1 Fields of application 15 5 2 Working pressure 15 5 3 Detergents 15 5 4 Working methods 16 6 0 Maintenance 17 6 1 Oil 17 6 2 Sludge conta...

Page 4: ...sumption Amps 9 Power absorption 10 Pump pressure 11 Capacity 12 Max pressure 13 Max temperature ALTO Danmark A S 72 18 21 00 1 2 Technical data Model 52C3KSA 1 52C3KSA 2 Pump pressure 1 psi 2600 2600...

Page 5: ...ine itself z WARNING Never try to clean clothes or footwear on yourself or other persons z Wear eye protection during operation z Never work barefoot or with sandals z WARNING The operator and anyone...

Page 6: ...it may be dangerous to use your pressure washer GROUNDING INSTRUCTIONS This product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electrical...

Page 7: ...portant parts of the equipment are damaged i e safety devices high pressure hoses spray handles cabinet z If the power cord is damaged it should be replaced by a ALTO trained service technician or a q...

Page 8: ...hine Connect the machine to an approved receptacle near the machine so that it will be possible to switch off power Check voltage fuse and cords according to section 2 1 Power requirements can be foun...

Page 9: ...the pump have been drained in any other way the system should be vented as follows 1 Start pump no 1 and let the water run from an outlet point of the pipe line When connecting a high pressure hose di...

Page 10: ...er temperatures above 120 F In the case of a pipeline with fixed outlet points a high pressure hose with imprinted working pressure and temperature should be attached to the nipple of the high pressur...

Page 11: ...high pressure cock To be used in conjunction with foam lance for application of high foaming detergents or disinfectants Metering range 1 5 Cleaning cart with foam injector and reel To be attached to...

Page 12: ...spray lance set for high pressure is attached If pressure does not build vent the machine as described in section 3 4 Venting Check oil level Turn to Position 1 Pump no 1 in operation Position 2 Pump...

Page 13: ...ovides change of approx 725 psi Low pressure mode When the reducing valve 1 is completely opened A the pressure will be fully reduced The nozzle pressure will be approx 60 psi In this position both sp...

Page 14: ...let pos 2 and activate spray lance or high pressure cock to relieve the pipeline high pressure hose of pressure 4 7 Operating environment installation The system should be installed in a frost free ro...

Page 15: ...most efficient cleaning is reached with detergents in conjunction with the high pressure cleaning For that purpose ALTO can offer you a series of products specially developed for high pressure cleani...

Page 16: ...f detergent STEP 2 High pressure cleaning agitation In practice the working process is determined by the actual task but as a starting point the following method can be described for a job 1 Apply det...

Page 17: ...100 When refilling and chang ing the oil this or an oil with the following specifications should be used ISO no 100 Viscosity index VI min 130 Pour point below 30 C 6 2 Sludge container waste tray As...

Page 18: ...high pressure cocks not in use point not completely closed KSA 1 Water regulation valve not Completely open the water regulation valve set at max pressure Turn in the direction of the indicator KSA 2...

Page 19: ...19...

Page 20: ......

Page 21: ......

Page 22: ...22...

Page 23: ...23...

Page 24: ...24 630 79 67 00 10 Printed in Denmark Copyright 2000 2001 ALTO Danmark A S ALTO Danmark A S Industrikvarteret DK 9560 Hadsund Tel 45 7218 2100 www alto online com...

Reviews: