1 2 • 2 0 M W / 2 0 • 2 0 M W O p e r a t i o n & C a r e M a n u a l • 1 5
A. No power.
Display will not light.
1. Verify that power is available at the outlet or junction box.
2. Verify that the circuit breaker switch on the back of the unit is turned on.
3. Verify that the power cord is not open. Check continuity with a VOM meter.
4. If none of the above steps help, call a qualified service technician or refer to the Service Manual for this
particular cabinet.
B. Display is lit and unit calls for heat, but unit is not heating;
Error Code E-30
Check to verify that the high limit switch located at the rear of the unit top has not been tripped. If it has been
tripped, reset by pressing the high limit reset button at the rear of the oven.
After resetting, the cause of the high limit trip must be corrected. If the high limit switch will not reset, the high
limit switch is defective and must be replaced.
This is a safety device and must not be jumped out or removed
from the circuit.
C. To test air sensor:
Test air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale. The
reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to
be replaced.
D. To test probe sensor:
Test food probe by placing in ice water bath and using an ohmmeter set on the ohm scale. The reading
should be 100 ohms resistance.
TROUBLE SHOOTING INTERNAL ELECTRICAL COMPONENTS
This section is provided for the assistance of qualified technicians only and is not intended for use by
untrained or unauthorized service personnel.
If your Alto-Shaam
®
unit is not operating properly, check the
following before calling your Authorized Alto-Shaam
®
Service Agent:
☛
Check the power flow to the unit. Plug in outlet? Circuit breaker switch at back of unit turned on?
Do not attempt to repair or service the Holding Cabinet unit beyond this point.
Contact Alto-Shaam
®
for
the nearest authorized service agent. Repairs made by any other service agents without prior
authorization by Alto-Shaam
®
will void the warranty on the unit.
D A N G E R
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
N O T E
If the appliance has been unplugged for an
extended period of time, the Real Time Clock may
require recharging. Turn main breaker to the unit
off for 10 seconds and then restore power.
For more information, see Error Code E-60 in
the Troubleshooting section of this manual.
C A U T I O N
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.