6.6"
(168mm)
Allow 3" (76mm) below
cartridges for replacement.
26"
(660mm)
BWS BLENDED WATER SYSTEM
ITEM FI-28727
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A.
phone
:
262.251.3800 800.558.8744
u
.
s
.
a
./
canada
fax
:
262.251.7067 800.329.8744
u
.
s
.
a
.
only
website
:
www.alto-shaam.com
printed
in
u
.
s
.
a
#465 - 05/10
due
to
ongoing
product
improvement
,
specifications
are
subject
to
change
without
notice
.
It is recommended that PreFilters be changed
every 3-6 months, when capacity is reached
or when inlet water pressure or flow becomes
inadequate. Change the ScaleX2
®
cartridge
annually. Membrane life varies depending on
inlet water conditions and PreFilter maintenance.
12-18 months under typical conditions but it can
be as long as 3-5 years.
This product is for commercial use only and
must be installed and maintained according to
manufacturers guidelines.
Do not use on water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
INLET WATER CHEMISTRY
Feed TDS
Up to 1200 ppm Iron
0.1 mg/l max
Feed pH
6-10
Turbidity
0.05 NTU
Hardness*
28 grains or less Manganese 0.05 mg/l max
Free Chlorine <2 mg/l
Hydrogen
Sulfide
0.0 mg/l
* For water outside of these parameters call technical service.
SYSTEM
Dimensions - Processor Tank
(
h
x
w
x
d
)
30.5" x 26" x 6.6"
(775mm x 660mm x 168mm)
41" x 24"dia.
(1,041mm x 610mm)
Inlet Water Connection
3/8” Push Fit Tubing
Operating Pressure Range
50-85 psi at 1 gpm (3.5 - 5.9 bar)
Inlet Water Temperature Range
40º - 100º F (4º - 38º C)
Shipping Weight
100 lbs. (45kg)
Power Requirements
(Within 5' of unit)
Processor
RP Pump
120V 15A circuit
120V 15A circuit
Drain Connection
(Within 5' of unit)
2 GPM Minimum Flow
PERFORMANCE
Typical TDS* Rejection
97+%
Product Water Production (at 77ºF, 60psi)
Production rate is strictly dependent on feed
water temperature and pressure.
350 gals (1325L)/day
14.6 gals (55L)/hr
0.25 gpm
Blended Water Production
Up to 400 GPD
Repressurization Pump (Self-priming)
0.25-2.75gpm at 50 psi
ACCESSORIES
Replacement Filter cartridge AMS-QT
FI-29316
Replacement Filter cartridge SCLX2-Q
FI-29317
Replacement
PreFilter
Filter cartridge CTO-Q
FI-29318
INSTALLATION REQUIREMENTS
•
Connection to system should be
to the cold water inlet only.
•
Do not exceed system specifications for
temperature and pressure.
•
Provide a dedicated 3/4" water line to the unit to
consistent flow and pressure to the system.
•
Allow 3" (76mm) clearance below system for filter
cartridge removal and replacement.
•
Connect filtered water line to steam production
connections only. Do not use for condenser water.
•
Detailed installation, operation & maintenance
manual is included with each system.
•
Mount the BWS-QT processor where the Water
Quality Monitor and ByPass Valve can be easily
viewed and accessed.
24"
(610mm)
30.5"
(775mm)
41"