T R O U B L E S H O O T I N G
44
CombiTouch ERROR CODES
Error
Code
Error Call Out in Display
Description of Error
Possible Cause
E34
Steam Generator Drain
Pump Fault
Water level in steam
generator does not drop
during cleaning program
— Scale build up inside the steam generator drain
pump.
— Scale build up inside the steam generator affecting
water level probes.
— Generator drain pump is faulty
— Connection issue at drain pump.
— No output to pump from relay board.
E36
Steam Temperature High
Oven cavity temperature is
too high when operating in
a steam mode or cleaning
program
— Water supply is shut off.
— Low water pressure.
— Wiring or connection issue.
— Water injection pipe obstructed.
— Water fl ow control valve plugged or defective.
— Dual solenoid valve Y-1 obstructed or defective.
— No output to solenoid valve form relay board.
E51
No Water In Boiler
Water inside steam generator
does not reach low water
level
— Water supply is shut off.
— Low water pressure.
— Generator drain cap missing or loose.
— Generator drain pump is not sealing.
— Generator drain pump elbow leaking.
— Faulty or scaled water level probe.
— Faulty or plugged dual solenoid valve assembly.
— Wiring or connection issue.
— No output to dual solenoid from relay board.
E53
Fan Motor High
Temperature
Fan motor too hot
— Exhaust hood is not operating properly.
— Check LED fl ashes on the Motor Control.
—
See Motor Control Error Code list
.
— Connection Issue on Hall Effect sensor.
— Fan wheel is not operating.
— Hall sensor does not detect motor rotation.
E54
Fan Motor 2 High
Temperature
20•20 lower fan motor too hot
— Exhaust hood is not operating properly.
— Check LED fl ashes on the Motor Control.
—
See Motor Control Error Code list
.
— Connection Issue on Hall Effect sensor.
— Fan wheel is not operating.
— Hall sensor does not detect motor rotation.
E55
Vent not open
Browning valve does not
open
— Alignment issue between motor cam and vent
motor safety switch (micro switch).
— Fault vent valve (motor).
— Fault vent valve safety switch (micro switch).
— Wiring or connection problem.
(CONTINUED ON NEXT PAGE)
Summary of Contents for 7.14esG CombiTouch
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......