# 6 0 0 1
C O M B I T H E R M E L E C T R I C I N S TA L L AT I O N A N D M A I N T E N A N C E M A N U A L
P G
. 2 8
It is
VERY
important to decalcify the oven, particularly in
areas with extremely hard water.
PERFORM ONCE A MONTH
in addition to the daily steam generator flush.
WITH THE OVEN AT ROOM TEMPERATURE
1.
Begin decalcification with the power switch in the OFF position.
2.
Rotate the Steam Generator Drain Cap
until water begins to flow from the four holes in the cap. In
approximately 20 to 60 seconds, a sufficient quantity of water will have drained from the steam generator so
that the drain cap can be completely removed.
3.
As the water continues to flow from the
generator, it will have a milky or cloudy
appearance, which indicates deposits in
the generator system are beginning to
flush out. Let the water continue to
drain until the flow completely subsides.
Replace the Steam Generator Drain
Cap
by turning it clockwise until
there is a slight resistance.
4.
Unscrew the cap from the
Decalcification Port
. With the
use of a funnel, pour one-half gallon
(c. 2 liters) of distilled white vinegar into
the Decalcification Port.
5.
Replace the cap on the Decalcification Port
and tighten securely.
S c a l d i n g w a t e r w i l l e r u p t f r o m t h e D e c a l c i f i c a t i o n
P o r t
w h e n t h e o v e n i s o p e r a t i n g u n l e s s t h e c a p
i s r e p l a c e d a n d t i g h t e n e d .
C O M B I T H E R M
®
D E C A L C I F I C AT I O N
ST
ANDARD CONTROL
DELUXE CONTROL
STANDARD CONTROL
DELUXE CONTROL
Summary of Contents for 10-10ML
Page 17: ......
Page 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...
Page 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...
Page 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...
Page 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...