Installation And Setup
Power Requirements
WARNING! The maximum allowable input current is 20 Amps. Do not overload circuits! Lumi-
naires must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector.
Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit
protecteur. Ne surchargez pas les circuits!
The LED Work Light operates on 100 to 230VAC, single phase only and draws a maximum of 90
Watts. This luminaire can be connected to a dimmer or a dimmer-controlled circuit or a circuit
providing constant power..
Connecting Power
Units are powered via an AC input cable (sold separately) from 100 to 230VAC, 50/60Hz and draw approxi-
mately 90 Watts of power. The table below outlines the wire colors and their purpose.
WIRE COLOR
PURPOSE
Brown or Black
Main / (L)ine
Blue or White
(N)eutral
Green/Yellow or Green
Ground / Earth
The Work Light II Luminaire must be connected to and properly grounded to an viable earth
ground.
Neutral
Earth/Ground
Live
Table 1: AC Input Wiring
The WorkLight can be wired into a Phase Cut or Triac Dimmer. On each unit there is a Local Dim dial that
will allow to locally dim the unit when connected to constant power.
Mains Dimming
Dimming Notes: The WL-90 is designed as a set it and forget it luminaire that employs a local dim. control and
mains dim compatible power supply. When running on mains dim power please make sure that the local dim
control is set to full.
The Work Light II employs dimming technology that is compatible with many dimmer types, The overall
performance of the mains dim. functionality is based upon the dimmer type and its resolution. The WL II
has been designed as a “set it and forget it” luminaire and has a lower dimming resolution than that of our
performance mains dim. products. When both the WLII and the Altman Pegasus or Chalice are connected to
the same dimmer or type they will display dissimilar dimming curves.
Phase Cut AC Sine Wave
(from dimmer to fixture)
Normal AC Sine Wave
(from source to dimmer)
Note
: The Worklight should be connected to Constant Mains power when using the local dim
functions. When connected to a remote dimmer the Local Dim should be set to full on.