2.  Voltage 

Current across CAT-6 Cable: 2.9A (max) 

Inverter Voltage: 60V 

Current x Resistance = Voltage Drop 

Example: 

2.9A x 3Ω = 9V 

Inverter Voltage 

– Voltage Drop = Voltage on Inverter 

Example: 

60V 

– 9V = 51V 

 

3.  Power 

Voltage on Inverter x Current = Power to Receiver 

Example: 

51V x 2.9A = 148W 

Power to Receiver -  Power Used by Receiver = Available Power 

Example: 

148W 

– 10W = 138W 

 

Available Surge Power Calculations (Example Calculations for 300ft Cable) 

1.  Voltage 

Surge Current: 4.5 A 

Surge Current x Resistance = Surge Voltage Drop 

Example: 

4.5A x 3Ω = 14V 

Inverter Voltage 

– Surge Voltage Drop = Surge Voltage on Inverter 

Example: 

60V 

– 14V = 46V 

 

2.  Power 

Surge Voltage x Surge Current = Surge Power 

Example: 

46V x 4.5A = 207W 

Surge Power to Receiver 

– Power Used by Receiver = Available Surge Power 

Example: 

207W 

– 10W = 197W 

Summary of Contents for MUSE MU600-001

Page 1: ...nce that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Page 2: ...n und 2 Dieses Ger t muss m gliche empfangene Funkst rungen und dadurch verursachte Funktionsst rungen akzeptieren Diese Anlage wurde getestet und unterliegt den gem Teil 15 der FCC Vorschriften f r d...

Page 3: ...of the transmitter unit is monitored for power consumption and when power is exceeded the output is turned off to protect all components The MUSE can power a 46 to 52 display with a maximum continuou...

Page 4: ...g berschritten wird wird die Ausgabe zum Schutz aller Komponenten abgeschaltet MUSE kann einen 46 52 Zoll Bildschirm mit maximalem Stromverbrauch von 150 Watt betreiben Der MU500 112 Receiver liefert...

Page 5: ...8 Application Diagram 9 Internal View Dimension Diagrams 10 Recommended Components Operation 11 Troubleshooting Guide 12 German Power Calculations 13 14 Technical Specifications 15 Application Diagram...

Page 6: ...50 228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Available Power Calculations Example Calculations for 300ft Cable 1 Resistance Resistance of a single strand of CAT 6 Cab...

Page 7: ...A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 1 Voltage Surge Current 4 5 A Surge Curren...

Page 8: ...Height 1 7 in 43 mm Width no mounting ears 4 3 in 109 mm Depth 8 7 in 221 mm Weight 2 0 lb 0 9 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 non condensing Table 2 MUSE Receiver Mechanical Elec...

Page 9: ...s Diagram 1 Typical Setup Table 5 Status of MU500 112 Receiver TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK ACTIVE ON LINK FAI...

Page 10: ...MU500 112 User s Guide 400 0598 002 10 Diagram 2 Receiver Internal View Diagram 3 Receiver Dimensions...

Page 11: ...have very large initial current requirements These are typically Plasma displays or low cost non Energy Star compliant displays If you have difficulty powering up a display adjust the settings to Eco...

Page 12: ...MU400 111 Transmitter If the problem is fixed wait 10 seconds and then reconnect the MU500 112 Receiver 3 Reconnect the display if the fault returns check the display power requirements Note There is...

Page 13: ...228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Verf gbare Leistungskalkulationen Beispielberechnung f r ein 91m Kabel 4 Resistance Resistance of a single strand of CAT 6...

Page 14: ...A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 3 Voltage Surge Current 4 5 A Surge Curren...

Page 15: ...r Height 1 7 in 43 mm Width no mounting ears 4 3 in 109 mm Depth 8 7 in 221 mm Weight 2 0 lb 0 9 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 non condensing Table 2 MUSE Receiver Mechanical Ele...

Page 16: ...ms Diagram 2 Typical Setup Table 5 Status of MU500 112 Receiver TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK ACTIVE ON LINK FA...

Page 17: ...MU500 112 User s Guide 400 0598 002 17 Diagram 2 Receiver Internal View Diagram 3 Receiver Dimensions...

Page 18: ...hirme mit hohen internen Stromanforderungen Es handelt sich dabei haupts chlich um Plasmabildschirme oder billige Anzeigen die nicht den Energy Star Anforderungen entsprechen Wenn Sie Schwierigkeiten...

Page 19: ...und schlie en den MU500 112 Receiver wieder an 3 Schlie en Sie den Bildschirm wieder an Wenn das Problem wiederkehrt pr fen Sie die Stromanforderungen des Bildschirms Hinweis Es steht ausreichen Strom...

Reviews: