background image

MUSE™: 

HDMI+POWER+IR Receiver

 

User’s Guide

 

 

400-0598-002 

 

 

 

Welcome!

Everyone  at  Altinex  greatly  appreciates  your  purchase  of  the  MUSE 
Receiver.  We  are  confident  you  will  find  it  reliable  and  simple  to  use.  If 
you need support, please do not hesitate to call us at 714-990-2300. 

  

We are committed to developing unique and state of the art Signal 
Management Solutions

®

 for demanding audiovisual installations. Welcome 

to the Altinex family of satisfied customers around the world. 

 
1. Precautions and Safety Warnings 

Please read this manual entirely before using your MU500-112 Receiver. 
You can download a full version of this manual o

www.altinex.com

These safety instructions are to ensure the reliable operation of your 
MU500-112 Receiver and to prevent fire and shock hazards. Please read 
them carefully and heed all warnings. 

1.1 General 

 

The MU500-112 Receiver does not contain any user serviceable 
parts. Only qualified ALTINEX service personnel may perform 
product service. 

 

The MU500-112 Receiver is safety tested and is ETL listed.  

 

The MU500-112 Receiver incorporates a proprietary technology for 
transmission of display power and video over a low voltage CAT-6 
cable. 

1.2 Installation Precautions 

 

To prevent fire or shock, do not expose this unit to water or 
moisture. Do not place the MUSE Receiver in direct sunlight, near 
heaters or heat-radiating appliances, or near any liquid. Exposure to 
direct sunlight, smoke, or steam can harm internal components. 

 

Handle the MU500-112 Receiver carefully. Dropping or jarring can 
cause damage. 

 

Do not pull any cables that are attached to the MU500-112 Receiver. 

 

For optimal safety when disassembling the MUSE Receiver, first 
unplug the power cord, which supplies power to both the 
transmitter and receiver, from the AC outlet.  

1.3 Cleaning 

 

Clean the MU500-112 Receiver only with a dry cloth. Never use 
strong detergents or solvents such as alcohol or thinner. Do not use 
a wet cloth or water to clean. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause 
undesired operation. 

 

This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instructions found herein, may cause harmful 
interference to radio communications. Operation of this equipment 
in a residential area is likely to cause harmful interference in which 
case the user will be required to correct the interference at his own 
expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment.

2. Installation Procedures 

Note: 

The CAT-6 type cable is a critical component to the functionality of the unit. Use only the recommended cables for optimum performance. See the 
minimum cable requirements on the technical specifications page. 

Step 1. 

For detailed information, download and read the entire manual from (

www.altinex.com)

.  

Step 2. 

Connect the MU500-112 Receiver to the monitor using a standard HDMI cable. Plug the display power cord in to the AC receptacle on the MU500-
112 Receiver.  

Step 3. 

Connect the MU500-112 Receiver to the MU400-111 Transmitter using terminated, unshielded CAT-6 cable. 
Required cable gauge is AWG23 to achieve full power. (Note: Use MU400-111 Transmitter with Altinex 
MU500-112 Receiver only) 

Step 4. 

Apply AC power to the MU400-111 Transmitter. As soon as the transmitter detects the receiver, it will allow 
power to be transmitted to the receiver, followed by the HDMI signal.  It may take several minutes to monitor 
power up and see the image displayed on the monitor. 

Step 5. 

Connect the IR receiver to the MUSE Receiver; place the eye near the front of the display and secure with the adhesive provided. 

Step 6. 

The MUSE Receiver is now ready for operation.  

 
 
 
 

 
 
3. Limited Warranty/Return Policies 

Please visit the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. In the case of a unit needing repair, please fill out the RMA 

(return material authorization) form located on the bottom left hand corner of the Altinex homepage. Once filled out, please email the form to 
[email protected].

 

Summary of Contents for MUSE MU600-001

Page 1: ...nce that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Page 2: ...n und 2 Dieses Ger t muss m gliche empfangene Funkst rungen und dadurch verursachte Funktionsst rungen akzeptieren Diese Anlage wurde getestet und unterliegt den gem Teil 15 der FCC Vorschriften f r d...

Page 3: ...of the transmitter unit is monitored for power consumption and when power is exceeded the output is turned off to protect all components The MUSE can power a 46 to 52 display with a maximum continuou...

Page 4: ...g berschritten wird wird die Ausgabe zum Schutz aller Komponenten abgeschaltet MUSE kann einen 46 52 Zoll Bildschirm mit maximalem Stromverbrauch von 150 Watt betreiben Der MU500 112 Receiver liefert...

Page 5: ...8 Application Diagram 9 Internal View Dimension Diagrams 10 Recommended Components Operation 11 Troubleshooting Guide 12 German Power Calculations 13 14 Technical Specifications 15 Application Diagram...

Page 6: ...50 228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Available Power Calculations Example Calculations for 300ft Cable 1 Resistance Resistance of a single strand of CAT 6 Cab...

Page 7: ...A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 1 Voltage Surge Current 4 5 A Surge Curren...

Page 8: ...Height 1 7 in 43 mm Width no mounting ears 4 3 in 109 mm Depth 8 7 in 221 mm Weight 2 0 lb 0 9 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 non condensing Table 2 MUSE Receiver Mechanical Elec...

Page 9: ...s Diagram 1 Typical Setup Table 5 Status of MU500 112 Receiver TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK ACTIVE ON LINK FAI...

Page 10: ...MU500 112 User s Guide 400 0598 002 10 Diagram 2 Receiver Internal View Diagram 3 Receiver Dimensions...

Page 11: ...have very large initial current requirements These are typically Plasma displays or low cost non Energy Star compliant displays If you have difficulty powering up a display adjust the settings to Eco...

Page 12: ...MU400 111 Transmitter If the problem is fixed wait 10 seconds and then reconnect the MU500 112 Receiver 3 Reconnect the display if the fault returns check the display power requirements Note There is...

Page 13: ...228 175 148 223 200 146 218 225 144 213 250 142 208 275 140 202 300 138 197 Verf gbare Leistungskalkulationen Beispielberechnung f r ein 91m Kabel 4 Resistance Resistance of a single strand of CAT 6...

Page 14: ...A 148W Power to Receiver Power Used by Receiver Available Power Example 148W 10W 138W Available Surge Power Calculations Example Calculations for 300ft Cable 3 Voltage Surge Current 4 5 A Surge Curren...

Page 15: ...r Height 1 7 in 43 mm Width no mounting ears 4 3 in 109 mm Depth 8 7 in 221 mm Weight 2 0 lb 0 9 kg T Operating 10 C 50 C T Maximum 75 C Humidity 90 non condensing Table 2 MUSE Receiver Mechanical Ele...

Page 16: ...ms Diagram 2 Typical Setup Table 5 Status of MU500 112 Receiver TX STATUS POWER PAIR NORMAL ON ON IDLE ON SLOW BLINKING FAULT FAST BLINKING FAST BLINKING VIDEO STATUS LINK VIDEO LINK ACTIVE ON LINK FA...

Page 17: ...MU500 112 User s Guide 400 0598 002 17 Diagram 2 Receiver Internal View Diagram 3 Receiver Dimensions...

Page 18: ...hirme mit hohen internen Stromanforderungen Es handelt sich dabei haupts chlich um Plasmabildschirme oder billige Anzeigen die nicht den Energy Star Anforderungen entsprechen Wenn Sie Schwierigkeiten...

Page 19: ...und schlie en den MU500 112 Receiver wieder an 3 Schlie en Sie den Bildschirm wieder an Wenn das Problem wiederkehrt pr fen Sie die Stromanforderungen des Bildschirms Hinweis Es steht ausreichen Strom...

Reviews: