background image

                                                          MULTI-TASKER

10

7.3.  SUMMARY OF COMMANDS

1) [VER]:

Receives software version

2) [C]:

Receives status of the card

3) [ON]:

Turns on one input for a single
card or a group of cards

4) [OFF]:

Turns off one input for a single
card or a group of cards

5) [SW]:

Switch (activates the preset
path)

6) [WR]:

Groups multiple cards

7) [CLR]:

Clears a single group or multiple
groups

8) [G]:

Requests group data

9) [RD]: 

Displays the members in each
group

10) [SIG]:

Checks if signal presents.

11) [HELP]: Display commands.

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no
problems in the supplied 

MT104-102

; however, we

would like to offer suggestions for the following:

8.1 LED IS NOT LIT

Cause 1:

Card cage is not plugged in.

Solution:

Plug card cage in. If the LED lights,
the problem is solved. If the LED is
still not lit, see Cause 2.

Cause 2:

Card is not plugged in all the way.

Solution:

Push the card in all the way. If the
LED is still not lit, see Cause 3.

Cause 3:

Card cage slot has a problem.

Solution 1:

Test the card in other slots of the
card cage. If the slot was damaged,
the card may work in other slots. If
other slots work and the LED lights,
the problem is the card cage slot.
The card cage may require service.
Call ALTINEX at (714) 990-2300. If
the other slots do not work and the
LED is still not lit, see Solution 2.

Solution 2:

Take any other known good card
with an LED and verify that the slot
used is good by seeing if the other
card’s LED lights in that slot. If it
lights, then the original card may be
the source of the problem. Call
ALTINEX at (714) 990-2300.

8.2 LED IS BLINKING RED

If the LED on the card is blinking red, find the

error code. For example, if you are
using card 5 of unit 1, send the

[C5U1]

 command to see the status

and error code. Note that card 5
refers to slot 5.

Cause 1: The CPU on the card is not working

properly. If the CPU is not working,
you will receive an ER01 message.
The system will return feedback as
[

On1 ER01 C05]

 when using card 5 of

unit 1.ER01 Code:

 

CPU error

Summary of Contents for MULTI-TASKER MT104-102

Page 1: ...MULTI TASKER MANUAL PART NUMBER 400 0092 005 6 IN 1 OUT VGA SWITCHER CARD FOR MULTI TASKER ENCLOSURES USER S GUIDE MT104 102 TM...

Page 2: ...102 3 TECHNICAL SPECIFICATIONS 3 PRODUCT DESCRIPTION 4 APPLICATION DIAGRAM 4 APPLICATION 1 4 APPLICATION 2 5 INSTALLING YOUR MT104 102 6 OPERATION 6 RS 232 CONTROL 6 RS 232 INTERFACE 6 DESCRIPTION OF...

Page 3: ...use strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the card Do not clean or touch any component or PCB 1 4 FCC CE NOTICE This device complies with pa...

Page 4: ...number of VGA inputs the MT104 102 can be connected to an MT VGA SW Expansion card For more information on expansion see the MT104 104 MT103 106 product descriptions TECHNICAL SPECIFICATIONS 3 FEATUR...

Page 5: ...MULTI TASKER 4 PRODUCT DESCRIPTION 4 APPLICATION DIAGRAM 5 Application Diagram 1...

Page 6: ...MULTI TASKER 5 Application Diagram 2 Internal View of the MT104 102...

Page 7: ...Square brackets are part of the command 2 Use uppercase letters for all commands After processing a command an OK or ER will be returned as feedback if F is included at the end of a command string or...

Page 8: ...number connected to the output as a default configuration of the card 3 ON This command enables one input of a single card or a group of cards ONmCnUiS for a single card This command enables input m...

Page 9: ...m card input m from 1 6 Gk group number k from 1 9 Ui unit number i from 0 9 S saves command to memory Example 1 OFF1G1U1 Turns OFF input 1 for each card in group 1 of unit 1 2 OFFG1U1 Turns OFF all...

Page 10: ...r all groups of unit 1 send the CLR G U1 command 8 G This command is used to request group data With the command the user can identify which input or output of a particular group is on Command Format...

Page 11: ...If the LED is still not lit see Cause 3 Cause 3 Card cage slot has a problem Solution 1 Test the card in other slots of the card cage If the slot was damaged the card may work in other slots If other...

Page 12: ...ER04 message see Solution 2 Solution 2 Turn the system OFF and then ON again If there is still an error message see Solution 3 Solution 3 If there is still a problem call ALTINEX at 714 990 2300 8 3...