background image

                                                          MULTI-TASKER 

 
 
 
 
 

INSTALLING YOUR MT103-116 

6

 

Step 1.   

Slide the 

MT103-116

 into an available slot 

in the Multi-Tasker™ Enclosure in order to 
connect to the bus. Make sure that the 

MT103-116 

card fits into place. Secure 

the card to the Multi-Tasker™ by 
tightening the retainer screws located on 
the top and bottom of the 

MT103-116 

card.  

Step 2.

  The LED on the card panel will turn red 

indicating that the card is in full operation. 
A green LED indicates that a signal is 
present.  

Step 3.

  Connect a VGA cable from the video 

source to the input connector of the 

MT103-116

. Connect the output 

connectors of the 

MT103-116

 to the 

Receiver through a CAT-5 cable. 

TROUBLESHOOTING GUIDE 

We have carefully tested and have found no 
problems in the supplied 

MT103-116

; however, we 

would like to offer suggestions for the following:

 

 

8.1 LED IS NOT LIT

 

 

8.2 NO DISPLAY

 

8.1. LED IS NOT LIT 

 A) Cause 1:

  

Card cage is not plugged in.

 

    

Solution:     

Plug card cage in. If the LED  

                        lights, the problem is solved. If the   
                        LED is still not lit, see Cause 2.    

 B) Cause 2:  Card is not plugged in all the  
                        way. 

    Solution:

     Push the card in all the way. If  

                        the LED is still not lit, see Cause  
                       3. 

 C) Cause 3:  Card cage slot has a problem. 

   

Solution 1:   

Test the card in other slots of   

                        

the card cage. If the slot was 

                        damaged, the card may work in  

other slots. If other slots work and 
the LED lights, the problem is the 
card cage slot. The card cage may 
require service. Call ALTINEX at 
(714) 990-2300. If the other slots do 
not work and the LED is still not lit, 
see Solution 2.    

 

Solution 2:

     Take any other known good card  

with an LED and verify that the slot 
used is good by seeing if the other 
card’s LED lights in that slot. If it 
lights, then the original card may be 
the source of the problem. Call 
ALTINEX at (714) 990-2300. 

8.2 NO DISPLAY 

  A) Cause 1: The source has a problem.

 

     Solution:

    Check the source and make sure  

                        that there is a signal present and  
                        all  source  connections  are  correct. 
If  
                        the source is working and there is  
                        still no display, see Cause 2. 