background image

DISTRIBUTION AMPLIFIERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DAV0106-V1A2

 Distribution Amplifier. Keep this

manual handy for future reference. These safety
instructions are to ensure the long life of your

DAV0106-V1A2

 and to prevent fire and shock

hazard. Please read them carefully and heed all
warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DAV0106-V1A2

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DAV0106-V1A2

Distribution Amplifier on a flat, leveled surface
in a dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the

DAV0106-V1A2

 Distribution Amplifier in direct

sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.

 Handle the 

DAV0106-V1A2

 Distribution

Amplifier carefully because dropping or jarring
can damage internal components.

 Do not place heavy objects on top of the

DAV0106-V1A2

. If the is to be mounted to a

table or wall, use only Altinex made mounting
accessories, such as rack mount shelf
(

DA1293FC, DA1294FC

) and cables for

optimum setup.

 To turn off the main power, be sure to remove

the cord from the power outlet. The power
outlet socket should be installed as close to the
equipment as possible, and should be easily
accessible.

 Do not pull the power cord or any cable that is

attached to the 

DAV0106-V1A2

 Distribution

Amplifier.

 If the 

DAV0106-V1A2

 Distribution Amplifier is

not used for an extended period, disconnect the
power cord from the power outlet.

1.4 CLEANING

 Unplug the 

DAV0106-V1A2

 power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents, such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant, to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may

Summary of Contents for DAV0106-V1A2

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0067 003 PRODUCT REVISION 1 DAV0106 V1A2 1 IN 6 OUT VIDEO AUDIO DISTRIBUTION AMPLIFIER USER S GUIDE...

Page 2: ...rs with solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many s...

Page 3: ...A2 Distribution Amplifier carefully because dropping or jarring can damage internal components Do not place heavy objects on top of the DAV0106 V1A2 If the is to be mounted to a table or wall use only...

Page 4: ...llow the connection of video and audio amplifiers simultaneously The DAV0106 V1A2 Distribution Amplifier is a state of the art product with a bandwidth of 130MHz for video signals which enables it to...

Page 5: ...Enclosure Material 0 1 Al Finish Gray Top panel Lexan Height inches 1 75in 44mm Width inches 8 50in 216mm Depth inches 4 93in 125mm Weight 2 0lbs 0 91kg Ship Weight 4 0lbs 1 81kg T Operating 10 C 35 C...

Page 6: ...DISTRIBUTION AMPLIFIERS 5 APPLICATION DIAGRAM 5...

Page 7: ...gnal is less than perfect make sure that all connections are solid and high quality cables are used CONGRATULATIONS YOU ARE DONE OPERATION 7 The DAV0106 V1A2 will operate successfully as long as cable...

Page 8: ...resolution coax cable POWER CABLES PC5301US Power cable for US PS5302UK Power cable for England PS5303AU Power cable for Australia PS5304GR Power cable for Germany FREQUENTLY ASKED QUESTIONS 9 No Ques...

Page 9: ...erson to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product that has been repaired or altered outside of company s factory in an...

Reviews: