PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DAA0106-V0A2

 Distribution Amplifier. Keep this

manual handy for future reference. These safety
instructions are to ensure the long life of your

DAA0106-V0A2

 and to prevent fire and shock

hazard. Please read them carefully and heed all
warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DAA0106-V0A2

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DAA0106-V0A2

Distribution Amplifier on a flat, leveled surface
in a dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the

DAA0106-V0A2

 Distribution Amplifier in direct

sunlight, near heaters or heat radiating
appliances, or near any liquid. Exposure to
direct sunlight, smoke, or steam can harm
internal components.

 Handle the 

DAA0106-V0A2

 Distribution

Amplifier carefully because dropping or jarring
can damage internal components.

 Do not place heavy objects on top of the

DAA0106-V0A2

. If the is to be mounted to a

table or wall, use only Altinex made mounting
accessories, such as rack mount shelf
(

DA1293FC, DA1294FC

) and cables for

optimum setup.

 To turn off the main power, be sure to remove

the cord from the power outlet. The power
outlet socket should be installed as close to the
equipment as possible, and should be easily
accessible.

 Do not pull the power cord or any cable that is

attached to the 

DAA0106-V0A2

 Distribution

Amplifier.

 If the 

DAA0106-V0A2

 Distribution Amplifier is

not used for an extended period, disconnect the
power cord from the power outlet.

1.4 CLEANING

 Unplug the 

DAA0106-V0A2

 power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents, such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may

Summary of Contents for DAA0106-V0A2

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0078 003 PRODUCT REVISION 1 DAA0106 V0A2 1 IN 6 OUT AUDIO DISTRIBUTION AMPLIFIER USER S GUIDE ...

Page 2: ...tomers with solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DAA0106V0A2 1 in 6 out Audio Distribution Amplifier TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUID...

Page 3: ...0A2 Distribution Amplifier carefully because dropping or jarring can damage internal components Do not place heavy objects on top of the DAA0106 V0A2 If the is to be mounted to a table or wall use only Altinex made mounting accessories such as rack mount shelf DA1293FC DA1294FC and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet...

Page 4: ...with a bandwidth of 10Hz to 20kHz for audio signals TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION Audio GENERAL No of Inputs 1 Input Connector One 3 5 mm 5 pin Terminal Block No of Outputs 6 Output Connector Six 3 5mm Terminal Blocks Compatibility Stereo or Mono Audio Table 1 DAA0106 V0A2 General MECHANICAL Audio Material 0 1 Al Finish Gray Top Panel Lexan Height inches 1 75in 44mm Width inches ...

Page 5: ...DISTRIBUTION AMPLIFIERS 4 DESCRIPTION OF DAA0106 V0A2 4 ...

Page 6: ...DISTRIBUTION AMPLIFIERS 5 APPLICATION DIAGRAM 5 ...

Page 7: ...e amplifier to the display devices such as monitors or projectors Step 4 Verify that the quality of the output signal on all speakers is good If the quality of the output signal is less than perfect make sure that high quality cables are used and all connections are solid CONGRATULATIONS YOU ARE DONE OPERATION 7 The DAA0106 V0A2 will operate successfully as long as cables are attached properly and...

Page 8: ...0 250 feet CB5000PL 5BM0XXX5BM 5 BNC to 5 BNC high resolution coax cable CB5100PL 5BM0XXX5BM 5 BNC to 5 BNC super high resolution coax cable POWER CABLES PC5301US Power cable for US PS5302UK Power cable for England PS5303AU Power cable for Australia PS5304GR Power cable for Germany FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 What is a Distribution Amplifier A Distribution Amplifier is a devi...

Page 9: ...s judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very important to Altinex that you receive the products that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policy below Altinex will accept product returns for a period o...

Reviews: