background image

SWITCHERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DA1914SX 

Switcher. Keep this manual handy for

future reference. These safety instructions are to
ensure the long life of your 

DA1914SX

 and to

prevent fire and shock hazard. Please read them
carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DA1914SX

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the airflow through the device’s

fan or vents.

 When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-

Mounted Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DA1914SX

Switcher on a flat, level surface in a dry area
away from dust and moisture.

 To prevent fire or shock, do not expose this

unit to rain or moisture. Do not place the

DA1914SX

 Switcher in direct sunlight, near

heaters or heat radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke,
or steam can harm internal components.

 Handle the 

DA1914SX

 Switcher carefully.

Dropping or jarring can damage internal
components.

 Do not place heavy objects on top of the

DA1914SX

. If the 

DA1914SX

 is to be mounted

to a table or wall, use only a Altinex made
mounting accessories, such as the mount
mini-brackets 

DA1295SX 

(or 

RC5203CC

Contact Closure Switch w/6 foot cable)

 

and

cables for optimum setup.

 To turn off the main power, be sure to remove

the adapter from the power outlet. The power
outlet socket should be installed as near to the
equipment as possible, and should be easily
accessible.

 Do not pull the adapter or any cable that is

attached to the 

DA1914SX

 Switcher.

 If the 

DA1914SX

 Switcher is not used for an

extended period, disconnect the adapter from
the power outlet.

1.4 CLEANING

 Unplug the 

DA1914SX

 adapter before

cleaning. Clean surfaces with a dry cloth.
Never use strong detergents or solvents, such
as alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual, may
cause harmful interference to radio
communications. Operation of this equipment
in a residential area is likely to cause harmful
interference in which case the user will be

Summary of Contents for DA1914SX

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0010 003 PRODUCT REVISION 2 DA1914SX 2 IN 1 OUT RGBS AUTO SWITCHER USER S GUIDE...

Page 2: ...e most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers thro...

Page 3: ...SX If the DA1914SX is to be mounted to a table or wall use only a Altinex made mounting accessories such as the mount mini brackets DA1295SX or RC5203CC Contact Closure Switch w 6 foot cable and cable...

Page 4: ...nd OFF when a single active source is on Input 1 If a single active source is on Input 2 the default the manual control will not push to Input 1 In auto switch mode the DA1914SX is perfect for applica...

Page 5: ...4 Horizontal 15 200 kHz Vertical 30 190 Hz Cross talk 40dB 10 MHz Coupling DC Power External Power Adapter 9V 500mA included Power Consumption 3 watts max Table 3 DA1914SX Electrical DESCRIPTION OF D...

Page 6: ...nals When both signals are present the switcher will default to INPUT 2 APPLICATION DIAGRAM 5 4 3 MANUAL SWITCH MODE The DA1914SX can be controlled manually by connecting a contact closure control swi...

Page 7: ...ong as cables are attached properly and other technical specifications are followed ACCESSORIES 8 Model No Description RACK MOUNTING ACCESSORIES DA1295RM Mount mini brackets 2 L shape CONTACT CLOSURE...

Page 8: ...Video signals when placed in the GREEN position 6 How far can I run a signal through the DA1914SX The output of the DA1914SX allows signals to be driven through 100 feet of cable depending on the cab...

Page 9: ...products that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept product...

Reviews: