MATRIX SWITCHERS
19
end of the cable is connected to the RS-232
port of the
HOMERUN
Matrix Switcher.
ALTINEX HOMERUN CONTROL PROGRAM
1
Follow Step 1 of previous option.
2.
Load the
HOMERUN
control program on
WINDOW 95 from the START UP button,
PROGRAM option and Altinex tab.
3 Go to the SETUP TAB and verify that
current baud rate is set at 2400 baud
(default). Then from SET Baud Rate section
select 9600 baud and click the program
button to program the baud rate into all
attached
HOMERUN
modules.
Note: The
HOMERUN
Control Software can be
downloaded from the Altinex website
www.altinex.com
in the Download section.
CP-02
DB-9 pin
connector
Signal
description
Connection to
HOMERUN
Switcher’s
RS-232 port
1
Power
Ground
Ground
2
Receive
Transmit
3
Transmit
Receive
5 (short
to 6)
CTS (short
to pin 6)
-
6 (short
to 5)
DTR (short
to pin 5)
-
7
Signal
Ground
Ground
8
Power Input
(+5V)
-
9
Power Input
(8-12V
regulated)
+12V
Table 4.
CP-02
pin outs and connection to
HOMERUN
Switcher
Terminal Set-up
The
CP-02
remote terminal must be properly set
up before it will operate with the
HOMERUN
Matrix switcher. To set up the terminal, turn
power “ON” while holding the (
•
) period button on
the keypad, and the terminal will enter into set-up
mode. The high contrast liquid crystal display
will briefly flash the following message:
VW
set LCD viewing angle
0 through 7
TM
terminal mode
0
TD
turnaround delay
0
BR
baud rate
2
DF
data format
4
HS
handshake
0
LE
local echo
0
EN
line terminator
1
KC
key click
0
KR
key repeat
0
CU
cursor
0
To save changes Press
Recall 01
.
The
OK
message
will be displayed on the screen
for 1 second.
1.
Turn power to the
HOMERUN
OFF and
back ON. Press the
ENTER
key.
2.
The display will read: Altinex, Inc. 3.2
or
the
current software version.
Congratulations! Your
CP-02
terminal set up is
completed!
A. Power ON:
Turn ON the power to the
HOMERUN
by
plugging in the power cord.
Observe the
CP-02
going into self-test mode for
about 5-6 seconds.
The display will flash the following message:
The
CP-02
remote terminal is now ready to
control the
HOMERUN
Matrix Switcher.
B. Function Keys description:
CONNECT
Allows user to make
connections between inputs
and outputs.
SAVE
Permits the connections
between inputs and outputs
Vol 1. Test OK
VW=7
Altinex, Inc. 3.2