![Altimium SW41H2-4K User Manual Download Page 29](http://html1.mh-extra.com/html/altimium/sw41h2-4k/sw41h2-4k_user-manual_2911241029.webp)
HDMI 2.0 4x1 Presentation Switcher with Audio Extraction
www.altimium.com
8.2.7 Button Command Setting
CMDON/+[X]/[Y]:xxx.
When power on the switcher, set
the command “xxx” to send to the
third-party device whose baud
rate is X.
When press the
DISPLAY ON
button, send the command “xxx”
to the third-party device whose
baud rate is X.
X
Baud Rate
1
2400
2
4800
3
9600
4
19200
5
38400
6
57600
7
115200
The “Y” can be 0 or 1.
If the “Y” is “0”, clear the saved
command “xxx”.
If the “Y” is “1”, automatically
send the command “xxx” to the
third-party device when power on
the switcher.
CMDON/+3/0:455665.
CMDON/+3/1:455665.
CMD_ON Save Success!
455665
[X]/[Y]:xxx.
When power off the switcher, set
the command “xxx” to send to the
third-party device whose baud
rate is X.
When press the
DISPLAY OFF
button, send the command “xxx”
to the third-party device whose
baud rate is X.
X
Baud Rate
1
2400
2
4800
3/0:455666.
3/1:455666.