Installation manual
8
EKRTR + EKRTETS
Room thermostat
4PW45518-1B
3.3.
Installation of the receiver
Typically the receiver needs to be installed next to the
AD
indoor unit.
Recommendations for an optimum signal
reception
Take the installation suggestions for the receiver into account
when selecting the installation location and follow the
recommendations below.
■
Do not install the receiver inside a metal box.
■
Mount the receiver vertically, and minimum 10 cm away
from the
AD
indoor unit.
■
Mount the receiver minimum 10 cm away from any vertical
metal pipe or vertical electric circuit.
■
Mount the receiver at least 1.5 m above the ground.
Before obtaining access to terminals, all power
supply circuits must be interrupted.