Installation manual
25
EKHBH/X016AB
Indoor unit for air to water heat pump system
4PW42457-1
T
ECHNICAL
SPECIFICATIONS
General
Electrical specifications
Heating/cooling models (EKHBX)
Heating only models (EKHBH)
Nominal capacity
• cooling
Refer to the Technical Data
• heating
Refer to the Technical Data
Dimensions H x W x D
922 x 502 x 361
922 x 502 x 361
Weight
• machine weight
55 kg
55 kg
• operation weight
70 kg
70 kg
Connections
• water inlet/outlet
1-1/4" MBSP
(a)
1-1/4" MBSP
• water drain
hose nipple
hose nipple
• refrigerant liquid side
Ø9.5 mm (3/8 inch)
Ø9.5 mm (3/8 inch)
• refrigerant gas side
Ø15.9 mm (5/8 inch)
Ø15.9 mm (5/8 inch)
Expansion vessel
• volume
10 l
10 l
• maximum working pressure (MWP)
3 bar
3 bar
Pump
• type
water cooled
water cooled
• no. of speed
2
2
Sound pressure level
(b)
28 dBA
28 dBA
Internal water volume
5.5 l
5.5 l
Pressure relief valve water circuit
3 bar
3 bar
Operation range - water side
• heating
+15~+55°C
+15~+55°C
• cooling
+5~+22°C
—
Operation range - air side
• heating
–20~+35°C
–20~+35°C
• cooling
+10~+46°C
—
• domestic hot water by heat pump
–20~+35°C
–20~+35°C
(a) MBSP = Male British Standard Pipe
(b) At 1 m in front of the unit (free field condition)
Heating/cooling models (EKHBX)
Heating only models (EKHBH)
Standard unit (power supply via outdoor unit)
• power supply
230 V 50 Hz 1P
• nominal running current
See outdoor unit installation manual
Backup heater
• power supply
See
"Connection of the backup heater power supply" on page 12
• maximum running current
See